Maytag ACO1860AS, ACO1840AC, ACO1560AB, ACO1530AB, ACO1840AB, ACO1560AC, ACO1560AS Testing Procedures

Page 9

Testing Procedures

!

WARNING

Disconnect power before performing the following

procedures unless testing requires it.

 

 

 

NOTES:

 

Interlock Monitor Switch Test

Perform microwave energy leakage test if unit is serviced for any reason.

Verify wire leads are connected to correct positions.

When removing wire terminal plugs from connectors, grasp the connector, not the wires.

Primary Interlock Switch Test

When the door is opened slowly, an audible click should be heard. If the latch does not activate the switch when the door is closed, the switch should be adjusted in accordance with the adjustment procedure.

1.Disconnect power to oven and remove control panel, (see “Control Panel” section in Disassembly Procedure).

2.Discharge high voltage capacitor, (see "High Voltage Capacitor" section in Disassembly Procedure).

3.Disconnect wire leads from switch.

4.Perform a continuity test by connecting one meter lead on COM terminal and the other meter lead on NO terminal.

Readings should be as follows: Door closed ................. 0 ohms Door opened ............... Infinite ohms

When the door is opened slowly, an audible click should be heard. If the latch does not activate the switch when the door is closed, the switch should be adjusted in accordance with the adjustment procedure.

1.Disconnect power to oven and remove control panel, (see “Control Panel” section in Disassembly Procedure).

2.Discharge high voltage capacitor, (see "High Voltage Capacitor" section in Disassembly Procedure).

3.Disconnect wire leads from switch.

4.Perform a continuity test by connecting one meter lead on COM terminal and the other meter lead on NC terminal.

Readings should be as follows: Door closed ................. Infinite ohms Door opened ............... 0 ohms

NOTE: When replacing component use identical replacement part.

NOTE: After repairing the door or the interlock system, it is necessary to do a continuity test before operating the oven.

NOTE: When replacing component use identical replacement part.

NOTE: After repairing the door or the interlock system, it is necessary to do a continuity test before operating the oven.

Secondary Interlock Switch Test

When the door is opened slowly, an audible click should be heard. If the latch does not activate the switch when the door is closed, the switch should be adjusted in accordance with the adjustment procedure.

1.Disconnect power to oven and remove control panel, (see “Control Panel” section in Disassembly Procedure).

2.Discharge high voltage capacitor, (see "High Voltage Capacitor" section in Disassembly Procedure).

3.Disconnect wire leads from switch.

4.Perform a continuity test by connecting one meter lead on COM terminal and the other meter lead on NO terminal.

Readings should be as follows: Door closed ................. 0 ohms Door opened ............... Infinite ohms

NOTE: When replacing component use identical replacement part.

NOTE: After repairing the door or the interlock system, it is necessary to do a continuity test before operating the oven.

Magnetron

1.Disconnect power to oven and remove control panel, (see “Control Panel” section in Disassembly Procedure).

2.Discharge high voltage capacitor, (see "High Voltage Capacitor" section in Disassembly Procedure).

3.Disconnect wire leads to magnetron.

4.Measure the resistance across filament terminals of the magnetron.

Reading should be less than 1 ohm.

5.Measure the resistance from each filament terminal to ground. Reading should indicate infinite ohms.

NOTE: Any other readings then what should be indicated, magnetron needs to be replaced.

NOTE: Replace the magnetron, if magnetron indications are good and all other high voltage components test good, but the unit still does not heat a load.

High Voltage Transformer

1.Disconnect power to oven and remove control panel, (see “Control Panel” section in Disassembly Procedure).

2.Discharge high voltage capacitor, (see "High Voltage Capacitor" section in Disassembly Procedure).

3.Disconnect wire leads to high voltage transformer.

©2002 Maytag Appliances Company

9

16021668 Rev. 0

Image 9
Contents Service Recognize Safety Symbols, Words, and Labels Customer Service Support CenterImportant Information Web Site Telephone NumberTable of Contents Important Product Information WiringGrounding Instructions Servicing of Grounded ProductsImportant Safety Information Microwave Leakage Testing General Information Microwave Oven Description Vent grilleOven control Testing Procedures High Voltage Diode High Voltage CapacitorHumidity Sensor RelayACO1560/MMV5156 models Pad Conn ACO1520/ACO1530 models Pad ConnACO1560/MMV5156 models ACO1840/MMV4184 models Pad ConnOven Thermostat Circuit BoardFuse Fan MotorTroubleshooting Procedures Adjust or Wire across Replace high Thermostat When Start pad is Check Power Supply Fuse Door Assembly Disassembly ProceduresDoor Disassembly GrilleBoard Control PanelControl Panel Removal Relay ACO1520*, ACO1530*, and MMV5156Outer Case Power TransformerScrew Control Panel Circuit Board RelayInterlock Door Latch Switches Stirrer Assembly some modelsDiode Adjusting InterlocksACO1840*, ACO1860*, JMV8196 MMV4184*, and MMV5186 High Voltage Capacitor RemovalPower Transformer Removal Magnetron Fan AssemblyTransformer Fuse RemovalMagnetron Thermal Fuse Magnetron Thermal FuseFan Motor Humidity Sensor RemovalLight Socket Base ThermostatTurntable Motor Vent BlowerWiring Diagram and Schematic ACO1560* and MMV5156* Models ACO18*, JMV8196*, MMV4184, and MMV5186* Models Appendix a Installation InstructionElectrical rating of this oven 120V AC 60Hz Avoid Electrical ShockDo not USE the Microwave Oven Do not expose yourself to excessive microwave energyTools and materials required for installation Parts, Tools, and MaterialsFollowing parts are supplied with the oven Preparing Venting System Preparing Electrical ConnectionRoof-Venting Roof VentingStandard Fittings Ductwork Length Room VentingWall Venting Installation Roof Venting InstallationRoom Venting Installation Recirculating Preparing Venting BlowerPreparing Wall and Upper Cabinet Preparing Template PlacementDrilling Holes in the Wall and Upper Cabinet Installing Mounting PlateAttaching Oven to the Wall Damper This page intentionally left blank Appendix B Care and Cleaning Cleaning the Grease FiltersCharcoal Filter Replacement Oven Light Replacement Cooktop/Night Light Replacement