Maytag ACO1560AW Outer Case, Screw Control Panel Circuit Board, Relay, Power Transformer

Page 20

Disassembly Procedures

!WARNING

To avoid the risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitors before following any disassembly procedure.

CN1

Main power connector

CN2

Primary switch

CN5

Humidity sensor (some models)

FPC (S1)

Ribbon connector for key panel

Relay 2

Relay connector

Screw Control Panel

 

Circuit

 

Board

(CN5)

 

(CN2)

CN5

FPC (S-1)

 

connector

CN2

 

Relay 2

Power

 

Transformer

 

 

CN1

ACO1840*, ACO1860*, JMV8196*,

MMV4184*, and MMV5186*

P.C. Board Removal

1.Disconnect oven power and remove grille, (see "Grille" procedure).

2.Remove control panel, (see "Control Panel" procedure).

3.Discharge high voltage capacitor, (see "High Voltage Capacitor" procedure).

4.Disconnect ribbon connector by sliding top part of connector upward. Once in released position remove ribbon from connector by siding ribbon side-to-side.

NOTE: Caution should be used when removing cable from connector. Ribbon cable has two holes which connector locks ribbon in place.

5.Disconnect and mark the wire connectors from p.c. board.

6.Remove screws securing p.c. board to control panel assembly.

7.Reassemble in reverse order.

NOTE: Do not flex p.c. board.

Control Key Panel

The key panel has one ribbon connection on the p.c. board.

The key panel pads can be checked through a continuity test. Operations of key pad can be checked by measuring connections at end of ribbon, (using high ohms scale).

Plastic fastener

Hook

Holes

F.P.C.

connector

Terminal socket

Control Key Panel Removal

1.Disconnect power to oven.

2.Remove control panel, (see "Control Panel" section).

3.Discharge high voltage capacitor, (see "High Voltage capacitor section).

4.Disconnect ribbon connector by sliding top part of connector upward. Once in released position remove ribbon from connector by siding ribbon side-to-side.

NOTE: Caution should be used when removing cable from connector. Ribbon cable has two holes which connector locks ribbon in place.

5.Peel failed key pad off and replace with new key pad.

6.Reassemble in reverse order.

Outer Case

NOTE: This procedure requires removal of unit.

1.Disconnect power to oven and remove grille, (see "Grille" procedure).

2.Remove oven door, (see "Door Removal" procedure).

3.Remove screws securing air duct to outer case.

4.Remove screws securing outer case to the chassis.

5.Remove screws securing vent plate to outer case.

6.Remove screw securing power cord cover to outer case and remove power cord cover (if equipped).

7.Slide outer case towards the rear of the unit, guide power cord though outer case power cord hole.

8.Place outer case to the side, so no damage will occur to the case.

16021668 Rev. 0

20

©2002 Maytag Appliances Company

Image 20
Contents Service Customer Service Support Center Recognize Safety Symbols, Words, and LabelsImportant Information Web Site Telephone NumberTable of Contents Wiring Important Product InformationGrounding Instructions Servicing of Grounded ProductsImportant Safety Information Microwave Leakage Testing General Information Oven control Microwave Oven DescriptionVent grille Testing Procedures High Voltage Capacitor High Voltage DiodeHumidity Sensor RelayACO1520/ACO1530 models Pad Conn ACO1560/MMV5156 models Pad ConnACO1560/MMV5156 models ACO1840/MMV4184 models Pad ConnCircuit Board Oven ThermostatFuse Fan MotorTroubleshooting Procedures Adjust or Wire across Replace high Thermostat When Start pad is Check Power Supply Fuse Disassembly Procedures Door AssemblyDoor Disassembly GrilleControl Panel BoardControl Panel Removal Relay ACO1520*, ACO1530*, and MMV5156Power Transformer Outer CaseScrew Control Panel Circuit Board RelayStirrer Assembly some models Interlock Door Latch SwitchesAdjusting Interlocks DiodeACO1840*, ACO1860*, JMV8196 MMV4184*, and MMV5186 High Voltage Capacitor RemovalMagnetron Fan Assembly Power Transformer RemovalTransformer Fuse RemovalMagnetron Thermal Fuse Magnetron Thermal FuseFan Motor Humidity Sensor RemovalBase Thermostat Light SocketTurntable Motor Vent BlowerWiring Diagram and Schematic ACO1560* and MMV5156* Models ACO18*, JMV8196*, MMV4184, and MMV5186* Models Installation Instruction Appendix aAvoid Electrical Shock Electrical rating of this oven 120V AC 60HzDo not expose yourself to excessive microwave energy Do not USE the Microwave OvenFollowing parts are supplied with the oven Tools and materials required for installationParts, Tools, and Materials Preparing Electrical Connection Preparing Venting SystemRoof-Venting Roof VentingRoom Venting Standard Fittings Ductwork LengthRoof Venting Installation Wall Venting InstallationRoom Venting Installation Recirculating Preparing Venting BlowerPreparing Template Placement Preparing Wall and Upper CabinetInstalling Mounting Plate Drilling Holes in the Wall and Upper CabinetAttaching Oven to the Wall Damper This page intentionally left blank Appendix B Charcoal Filter Replacement Care and CleaningCleaning the Grease Filters Cooktop/Night Light Replacement Oven Light Replacement