Carrier 50KQL-1PD manual 50KQL Chassis Dimensions Size 07, 09, 12, 15

Page 13

50KQL CHASSIS DIMENSIONS — SIZE 07, 09, 12, 15, 19

40.98 (1040)

 

3.28

 

 

5.36

 

(83)

Power Supply

(136)

1.84

3.01

 

 

 

 

(47)

 

 

 

(76)

 

 

Water Out

30°

 

Control Box

 

 

0.87

 

Water In

 

 

 

 

(22)

 

 

 

 

20.50 (521)

0.75 (19)

Optional

Autoflow

Valve

Blower Deck

Blower Access Panel

Compressor

Access

Panel

4.46 (113)

0.75 (19)

*16.66

 

(423)

 

 

7.5

 

(191)

*1.94

 

(49)

 

*7.06

3.56

(179)

(90)

 

 

 

 

 

 

 

 

 

Condensate

3.88

 

 

 

 

 

 

 

 

0.99

 

3.43

5/8” (15.9 mm)

(99)

11.54

(87)

 

(25)

ID Vinyl Hose

 

(293)

 

 

 

 

 

 

 

 

 

Optional

Motorized

Water Valve

Water Connections 5/8” (15.9 mm) OD Copper, 1/2” FPT or 1/2” MPT Optional Disconnect Box (mounted to cabinet not chassis)

RIGHT HAND CONFIGURATION

5.36

 

 

3.50

40.98

(136)

Power Supply

(89)

(1041)

3.01

 

Water Out

 

1.93

(76)

 

 

(49)

 

Water In

 

 

30°

 

 

 

 

 

 

0.87 (22)

Control Box

7.5 (191)

3.56 (90)

3.42 (87)

3.22 (82)

*16.66 (423)

*1.94 (49)

*7.06 (179)

Condensate

3.885/8” (15.9 mm)

 

(99)

ID Vinyl Hose

11.54

 

 

 

 

 

4.49 (114)

0.75 (19)

Blower Deck

Blower Access Panel

Compressor

Access

Panel

0.75 (19)

20.44 (52)

Optional

Autoflow

Valve

Optional

Motorized

Water Valve

Water Connections 5/8” (15.9 mm) OD Copper, 1/2” FPT or 1/2” MPT

*For installed dimension, add to dimension shown 2.9 in. with 3 in. subbase and 4.9 in. for 5 in. subbase.

 

Notes:

 

NOTES:* For installed dimension, add to dimension shown 74mm with 76mm subbase and

1.

Dimensions124mm for shown127mm subbase.are in inches. Dimensions in parentheses are in millimeters.

2.

1.

Dimensions shown re in inches. D

nsions in parenth ses are in millimet rs.

Optional autoflow valve, motorized water valve and disconnect box are shown.

3.

2.

Optional autoflow valve, motorized water valve and disconnect box are shown.

Water connection in same location regardless of connection type.

 

3.

Water connection in same location regardless of connection type.

Optional Disconnect Box (mounted to cabinet not chassis)

LEFT HAND CONFIGURATION

13

Image 13
Contents Operating efficiency Features/BenefitsTable of contents Features/Benefits Q L 0 7 S a E C 1 0 1 a a Model number nomenclaturePhysical data ARI/ISO 13256-1 capacity ratingsFactory-installed options Options and accessories50KQL Control Options Table Field-installed accessoriesPremierlink Communicating Control Carrier Aquazone Thermostats50KQL Bottom Return Cabinet Dimensions Right Hand Piping DimensionsRear View Access Damper OP Ening 50KQL Bottom Return Cabinet Dimensions Left Hand PipingRear Access 50KQL Front Return Cabinet Dimensions Right Hand PipingRear Access Rear View 50KQL Front Return Cabinet Dimensions Left Hand Piping50KQL Chassis Dimensions Size 07, 09, 12, 15 Selection procedure with 50KQL12 example Page 50KQL07 Nominal Airflow 240 CFM Performance data12.2 50KQL09 Nominal Airflow 300 CFM12.3 11050KQL12 Nominal Airflow 350 CFM 17.6 13.8 50KQL15 Nominal Airflow 400 CFM13.9 10.4 17.6 15.1 50KQL19 Nominal Airflow 460 CFM16.7 11.5 21.1 Correction Factors Airflow Correction Factors Entering AIRWater loop system Application dataGround water systems Ground loop systemsWater conditioning Condensate drainageAcoustical design Water Quality GuidelinesConsole units Wshp sound controlOperating limits Starting conditionsManual Changeover with Complete C Controller Typical wiring schematicsCB* Note Manual Changeover with Deluxe D ControllerHigh FAN Automatic Changeover with Complete C ControllerUMT Automatic Changeover with Deluxe D ControllerREMOTE-MOUNTED Thermostat with Complete C Controller Transformer Water Valve Field Line Voltage WiringREMOTE-MOUNTED Thermostat with Deluxe D Controller Space Temperature Sensor Supply Air Temperature SensorPremierlink Controller Applications with Complete C Control Premierlink Controller Applications with Deluxe D Control50KQL Piping Detail Typical pipingConsole Water Source Heat Pumps Guide specificationsGuide specifications Page Carrier Corporation Syracuse, New York