Carrier 50KQL-1PD manual ARI/ISO 13256-1 capacity ratings, Physical data

Page 5

ARI/ISO 13256-1 capacity ratings

 

 

 

COOLING

 

 

HEATING

 

AIRFLOW

WATER

PRESSURE

UNIT 50KQL

TC

SC

THR

Input Power

EER

TC

Input Power

COP

(cfm)

FLOW

DROP

 

(kW)

(kW)

(gpm)

(ft wg)

 

 

 

 

 

 

 

 

07

7.8

6.6

10.0

0.645

12.1

10.4

0.622

4.9

240

1.9

1.5

09

9.3

7.2

11.9

0.775

12.0

12.0

0.799

4.4

300

2.5

3.1

12

12.3

9.5

15.9

1.060

11.6

15.0

0.999

4.4

350

3.1

3.8

15

13.8

11.2

17.8

1.169

11.8

17.3

1.152

4.4

400

3.6

3.0

19

16.0

11.9

20.6

1.333

12.0

19.3

1.346

4.2

460

4.8

5.0

LEGEND

ARI — Air Conditioning and Refrigeration Institute COP — Coefficient of Performance

db — Dry Bulb Temperature EER — Energy Efficiency Ratio

ISO — International Organization for Standardization TC — Total Capacity (MBtuh)

THR — Total Heat of Rejection (MBtuh) SC — Sensible Capacity (MBtuh) wb — Wet Bulb Temperature

NOTES:

1.Ratings are in accordance with and certified to ARI/ISO Standard 13256-1.

2.Cooling Standard: 80.6 F db, 66 F wb indoor entering air tempera- ture, 86 F entering water temperature.

3.Heating Standard: 68 F db indoor entering air temperature, and 68 F entering water temperature.

Physical data

BASE UNIT 50KQL

07

09

12

15

19

NOMINAL COOLING CAPACITY (Btuh)

7,800

9,300

12,300

13,800

16,000

 

 

 

 

 

 

COMPRESSOR

 

 

Rotary

 

 

 

 

 

 

 

 

BLOWER

1/20

1/15

1/15

1/6

1/6

Motor Horsepower

Wheel Size D x W (in.) 2 each

51/4 x 61/4

51/4 x 61/4

51/4 x 61/4

51/4 x 61/4

51/4 x 61/4

FILTER SIZE (in.) Bottom Return

8 x 291/2 x 3/8

8 x 291/2 x 3/8

8 x 291/2 x 3/8

8 x 291/2 x 3/8

8 x 291/2 x 3/8

FILTER SIZE (in.) Front Return

7 x 291/2 x 1/8

7 x 291/2 x 1/8

7 x 291/2 x 1/8

7 x 291/2 x 1/8

7 x 291/2 x 1/8

UNIT WEIGHT (lb)

 

 

 

 

 

Shipping

181

185

195

201

206

Operating

173

177

187

193

198

REF. TO AIR HEAT EXCHANGER

 

 

 

 

 

Face Area (sq ft)

1.4

1.4

1.4

1.8

1.8

No. of Rows Deep

2

2

3

3

3

Copper Tube Size OD (in.)

3/8

3/8

3/8

3/8

3/8

Fin Spacing (FPI)

13

13

13

13

12

REFRIG. CHARGE (R-22)/CKT (oz)

16

16

21

27

24

No. of Circuits

1

1

1

1

1

UNIT CABINET WITH STANDARD SUBBASE

 

 

 

 

 

W x H x D (in.)

48 x 24 x 12

48 x 24 x 12

48 x 24 x 12

48 x 24 x 12

48 x 24 x 12

WATER IN/OUT SIZE OD SWEAT (in.)

5/8

5/8

5/8

5/8

5/8

CONDENSATE SIZE ID VINYL (in.)

5/8

5/8

5/8

5/8

5/8

5

Image 5
Contents Operating efficiency Features/BenefitsTable of contents Features/Benefits Q L 0 7 S a E C 1 0 1 a a Model number nomenclaturePhysical data ARI/ISO 13256-1 capacity ratingsFactory-installed options Options and accessories50KQL Control Options Table Field-installed accessoriesPremierlink Communicating Control Carrier Aquazone Thermostats50KQL Bottom Return Cabinet Dimensions Right Hand Piping DimensionsRear View Access Damper OP Ening 50KQL Bottom Return Cabinet Dimensions Left Hand PipingRear Access 50KQL Front Return Cabinet Dimensions Right Hand PipingRear Access Rear View 50KQL Front Return Cabinet Dimensions Left Hand Piping50KQL Chassis Dimensions Size 07, 09, 12, 15 Selection procedure with 50KQL12 example Page 50KQL07 Nominal Airflow 240 CFM Performance data12.2 50KQL09 Nominal Airflow 300 CFM12.3 11050KQL12 Nominal Airflow 350 CFM 13.9 10.4 17.6 50KQL15 Nominal Airflow 400 CFM17.6 13.8 16.7 11.5 21.1 50KQL19 Nominal Airflow 460 CFM15.1 Correction Factors Airflow Correction Factors Entering AIRWater loop system Application dataGround water systems Ground loop systemsWater conditioning Condensate drainageAcoustical design Water Quality GuidelinesConsole units Wshp sound controlOperating limits Starting conditionsManual Changeover with Complete C Controller Typical wiring schematicsCB* Note Manual Changeover with Deluxe D ControllerHigh FAN Automatic Changeover with Complete C ControllerUMT Automatic Changeover with Deluxe D ControllerREMOTE-MOUNTED Thermostat with Complete C Controller Transformer Water Valve Field Line Voltage WiringREMOTE-MOUNTED Thermostat with Deluxe D Controller Space Temperature Sensor Supply Air Temperature SensorPremierlink Controller Applications with Complete C Control Premierlink Controller Applications with Deluxe D Control50KQL Piping Detail Typical pipingConsole Water Source Heat Pumps Guide specificationsGuide specifications Page Carrier Corporation Syracuse, New York