Carrier 50KQL-1PD manual REMOTE-MOUNTED Thermostat with Complete C Controller

Page 29

REMOTE-MOUNTED THERMOSTAT WITH COMPLETE C CONTROLLER

GROUND

POWER SUPPLY

REFER TO DATA PLATE

USE COPPER CONDUCTORS ONLY.

SEE NOTE 2

REFER TO DISCONNECT

BOX FOR OPTIONAL

POWER SUPPLY CONNECTION

 

NEUTRAL ON 265V

 

SYSTEMS

L2

RED

2

L1

PB

1

H

 

 

BLU

COMPRESSOR

 

 

S

CAP

 

 

 

 

8

 

R

C RED 6

RED

C

F

2

CR

 

 

4

BLK

BLK

OPTIONAL

 

L2 (ribbed)

 

 

BRN 2

 

B (HIGH)

 

GROUND

 

 

 

CORD

 

 

 

 

BM

 

 

CONNECTION

 

L1 (plain)

 

 

YEL

 

 

 

 

 

 

 

 

 

 

SEE

 

COM NO

BLK

1

A (LOW)

CB*

 

 

 

RED

NOTE 3

BLK

BLK

 

 

2

 

 

TRANS

BR

 

1

BLK

 

 

 

 

 

FSS

24V

 

ORG

 

 

 

 

 

 

 

 

 

 

 

 

230V

 

 

 

 

 

 

 

SEE

 

NOTE 7

BLK TRANS

RED

CB

(220V)

24V BLU

ORG (240V)

 

TYPICAL HEAT PUMP T-STAT BRN

YEL

 

YEL

ORG

 

 

 

TRANSFORMER PRIMARY

YEL

DM

BRN

 

SEE

LEAD COLORS

 

 

 

 

 

 

1

0

 

1 0

NOTE 7

VOLTAGE

LEAD COLOR

 

BR

 

CR

 

115

WHT

 

 

 

 

 

 

YEL GRY

BRN

BRN BRN

YEL

208

RED

230

ORG

 

 

 

 

 

 

 

BR

BRG

CCG

CC

 

265

BRN

 

 

 

 

 

 

 

C

TEST PINS

 

 

 

 

 

 

 

 

 

 

SEE NOTE 5

CLASS 1 WIRING

 

CLASS 1 OR 2

 

WIRING ACCEPTABLE

REQUIRED INSIDE

 

OUTSIDE

CONTROL BOX

 

CONTROL BOX

COMPRESSOR

 

Y

 

 

 

O

 

COOLING

 

 

 

 

G

 

FAN

 

 

 

 

R

 

24 VAC

 

 

 

 

C

 

COMMON

 

 

 

 

L

 

ALARM

 

 

 

 

BRN

WV

YEL

 

 

 

 

GROUND

 

 

CAP

PB

 

 

 

 

TRANSFORMER

 

R

Y

Y

W

O

G

R

C

AL1

AL2

A

P1

 

 

 

COMPR.

 

SEE

 

RELAY

 

NOTE 4

 

 

JW3

 

 

 

FP1

 

 

 

JW2

 

 

 

FP2

 

 

 

DIP SWITCH

 

 

1

PM: DISABLED/

 

 

2

ENABLED

 

 

STAGE 2: 2/1

 

 

3

NOT USED

 

 

4

NOT USED

 

 

5

FP1/FP2

JW1 OFF ON FAULTS: 3/1

 

 

 

STATUS

ALARM

SEE

 

G LED

RELAY

NOTE 6

COMPLETE C

MICRO-

PROCESSOR

CONTROL

LOGIC

CO

HP 1

RED

HP

RED

2

 

3

BLU

LOC

LOC

BRN

4

 

5

GRY

FP1

FP16

 

GRY

SEE

FP27

VIO

NOTE 4

FP2

8

VIO

 

RV 9

BRN

RVS

10

ORG

 

 

NOT USED

 

CO12

YEL

CO

P2

 

 

24V DC

EH1

EH2

P3

 

CR

 

 

BR

 

COMPLETE

 

 

C

 

 

CONTROL

 

 

LEGEND

 

AL

Alarm Relay Contacts

 

BM

Blower Motor

 

BR

Blower Relay

 

CAP

Capacitor

 

CB

Circuit Breaker

 

CO

Sensor, Condensate Overflow

 

CR

Compressor Relay

 

DM

Damper Motor

 

FP1

Sensor, Water Coil Freeze Protection

 

FP2

Sensor, Air Coil Freeze Protection

 

FSS

Fan Speed Switch

 

HP

High-Pressure Switch

 

JW1

Jumper Wire for Alarm

 

LOC

Loss of Charge Pressure Switch

 

PB

Power Terminal Block

 

PBS

Push Button Switch

 

PM

Performance Monitor

 

RVS

Reversing Valve Solenoid

 

TRANS

Transformer

>>

WV

Water Valve

----------Field Line Voltage Wiring

 

Field Low-Voltage Wiring

Printed Circuit Trace Relay/Contactor Coil

Solenoid Coil

Thermistor

Circuit Breaker

Relay Contacts-N.O.

Switch-High Pressure

Switch-Low Pressure

Ground

Wire Nut

Mate-N-Lock

BLOWER MOTOR WIRING

UNIT SIZE

POLE A

POLE B

07

5

3

09

5

4

12

4

3

15

4

3

19

4

3

*Optional wiring.

NOTES:

1.Compressor and blower motor thermally protected internally.

2.All wiring to the unit must comply with local codes.

3.Transformer is wired to 115-V (WHT) lead for 115/ 1/60 units, 265-V (BRN) lead for 265/1/60 units or 208-V (RED) lead for 208/1/60 units.

For 203/1/60 switch RED and ORG leads at L1 and insulate RED lead.

Transformer is energy limiting or may have circuit breaker.

4.FP1 thermistor provides freeze protection for WATER. When using ANTI-FREEZE solutions, cut JW3 jumper.

5.Typical heat pump thermostat wiring shown. Refer to thermostat Installation Instructions for wiring to the unit.

6.24-V alarm signal shown. For dry alarm contact, cut JW1 jumper and dry contact will be available between AL1 and AL2.

7.Transformer secondary ground via Complete C board standoffs and screws to control box. (Ground available from top two standoffs as shown.)

29

Image 29
Contents Operating efficiency Features/BenefitsTable of contents Features/Benefits Q L 0 7 S a E C 1 0 1 a a Model number nomenclaturePhysical data ARI/ISO 13256-1 capacity ratingsFactory-installed options Options and accessories50KQL Control Options Table Field-installed accessoriesPremierlink Communicating Control Carrier Aquazone Thermostats50KQL Bottom Return Cabinet Dimensions Right Hand Piping DimensionsRear View Access Damper OP Ening 50KQL Bottom Return Cabinet Dimensions Left Hand PipingRear Access 50KQL Front Return Cabinet Dimensions Right Hand PipingRear Access Rear View 50KQL Front Return Cabinet Dimensions Left Hand Piping50KQL Chassis Dimensions Size 07, 09, 12, 15 Selection procedure with 50KQL12 example Page 50KQL07 Nominal Airflow 240 CFM Performance data12.2 50KQL09 Nominal Airflow 300 CFM12.3 11050KQL12 Nominal Airflow 350 CFM 13.9 10.4 17.6 50KQL15 Nominal Airflow 400 CFM17.6 13.8 16.7 11.5 21.1 50KQL19 Nominal Airflow 460 CFM15.1 Correction Factors Airflow Correction Factors Entering AIRWater loop system Application dataGround water systems Ground loop systemsWater conditioning Condensate drainageAcoustical design Water Quality GuidelinesConsole units Wshp sound controlOperating limits Starting conditionsManual Changeover with Complete C Controller Typical wiring schematicsCB* Note Manual Changeover with Deluxe D ControllerHigh FAN Automatic Changeover with Complete C ControllerUMT Automatic Changeover with Deluxe D ControllerREMOTE-MOUNTED Thermostat with Complete C Controller Transformer Water Valve Field Line Voltage WiringREMOTE-MOUNTED Thermostat with Deluxe D Controller Space Temperature Sensor Supply Air Temperature SensorPremierlink Controller Applications with Complete C Control Premierlink Controller Applications with Deluxe D Control50KQL Piping Detail Typical pipingConsole Water Source Heat Pumps Guide specificationsGuide specifications Page Carrier Corporation Syracuse, New York