Carrier 50KQL-1PD manual 50KQL Bottom Return Cabinet Dimensions Left Hand Piping

Page 10

Dimensions (cont)

50KQL BOTTOM RETURN CABINET DIMENSIONS — LEFT HAND PIPING

12.6

(320)

Control Access Door

Filter located inside and at top of air inlet area. Push tabs back and down to release filter for replacement.

FRONT VIEW

1.5Discharge

(38)Air

30°

SIDE

VIEW

3.5

(88.9)

*23.9

(607)

1.9

(48)

1.75

(44.5)

AIR INLET AREA

33.5

(851)

48.0

(1219)

48.0

(1219)

Air

Inlet

11.5

(292)

12.0

(305)

*2.9

(74)

10.0

(254)

1.56

(40)

3.5

(89)

L.H. Pipe &

Electric Area

BOTTOM VIEW

0.75

(19)

 

 

4.5

 

 

(114)

REAR VIEW

REAR

 

ACCESS

 

1.63

 

 

(41)

 

 

DAMPER OPENING*

0.59

(15)

 

11.75

9.9

48.0

(298)

(251)

 

 

(1219)

 

 

1 (25)

1 (25)

21.0

(533)

20.0

(508)

*2.9

(74)

*Dimension shown is with 3 in. subbase. Add 2 in. to dimension shown for 5 in. subbase.

NOTES:

Notes:

1. Dimensions shown are in inches. Dimensions in parentheses are in millimeters.

 

1.DimensionsShownare76mmshownsubbase.in inches.Add Dimensions50.8mm to dimensionin parenthesesshown forare127mmin millimeterssubbase. .

2. Optional autoflow valve, motorized water valve and disconnect box are shown. 2. Optional autoflow valve, motorized water valve and disconnect box are shown.

10

Image 10
Contents Features/Benefits Operating efficiencyTable of contents Features/Benefits Model number nomenclature Q L 0 7 S a E C 1 0 1 a aARI/ISO 13256-1 capacity ratings Physical dataOptions and accessories Factory-installed optionsField-installed accessories 50KQL Control Options TableCarrier Aquazone Thermostats Premierlink Communicating ControlDimensions 50KQL Bottom Return Cabinet Dimensions Right Hand Piping50KQL Bottom Return Cabinet Dimensions Left Hand Piping Rear View Access Damper OP Ening50KQL Front Return Cabinet Dimensions Right Hand Piping Rear Access50KQL Front Return Cabinet Dimensions Left Hand Piping Rear Access Rear View50KQL Chassis Dimensions Size 07, 09, 12, 15 Selection procedure with 50KQL12 example Page Performance data 50KQL07 Nominal Airflow 240 CFM12.3 50KQL09 Nominal Airflow 300 CFM12.2 11050KQL12 Nominal Airflow 350 CFM 17.6 13.8 50KQL15 Nominal Airflow 400 CFM13.9 10.4 17.6 15.1 50KQL19 Nominal Airflow 460 CFM16.7 11.5 21.1 Correction Factors Entering AIR Correction Factors AirflowGround water systems Application dataWater loop system Ground loop systemsAcoustical design Condensate drainageWater conditioning Water Quality GuidelinesOperating limits Wshp sound controlConsole units Starting conditionsTypical wiring schematics Manual Changeover with Complete C ControllerManual Changeover with Deluxe D Controller CB* NoteAutomatic Changeover with Complete C Controller High FANAutomatic Changeover with Deluxe D Controller UMTTransformer Water Valve Field Line Voltage Wiring REMOTE-MOUNTED Thermostat with Complete C ControllerREMOTE-MOUNTED Thermostat with Deluxe D Controller Premierlink Controller Applications with Complete C Control Supply Air Temperature SensorSpace Temperature Sensor Premierlink Controller Applications with Deluxe D ControlTypical piping 50KQL Piping DetailGuide specifications Console Water Source Heat PumpsGuide specifications Page Carrier Corporation Syracuse, New York