Carrier 50KQL-1PD manual Field-installed accessories, 50KQL Control Options Table

Page 7

50KQL CONTROL OPTIONS TABLE

OPTION

 

CONTROLLER

THERMOSTAT

FUNCTIONS

TRANSFORMER

 

A

 

Complete C

MCO

50 VA

 

B

 

Deluxe D

MCO

NIGHT LOW LIMIT 2-HR OVERRIDE

75 VA

 

C

 

Complete C

ACO

50 VA

 

D

 

Deluxe D

ACO

NIGHT LOW LIMIT 2-HR OVERRIDE

75 VA

 

P

 

Complete C with PremierLink™

LINKAGE

DDC SYSTEM

50 VA

 

R

 

Complete C

REMOTE

50 VA

 

S

 

Deluxe D

REMOTE

NIGHT LOW LIMIT2-HR

75 VA

 

 

OVERRIDE

 

 

 

 

 

 

 

LEGEND

 

 

 

ACO

Auto Changeover

 

 

 

DDC

Direct Digital Controls

 

 

 

MCO

Manual Changeover

 

 

 

Field-installed accessories

Carrier’s line of Aquazone™ thermostats (used with remote thermostat units) are both attractive and multi- functional, accommodating stand-alone water source heat pump installations.

Programmable 7-day thermostat — Offers 2-stage heat, 2-stage cool, auto changeover, 7-day programmable with copy command, 4 settings per day, fully electronic, 24 vac, backlit LCD, keypad lockout, no batteries required, 5-minute compressor protection, NEVERLOST™ memory, 3 security levels, temperature display in degrees F or C.

Programmable 7-daylight-activated thermostat — Offers same features as the 7-day programmable thermostat and includes occupied comfort settings with lights on, unoccu- pied energy savings with lights off.

Programmable 7-dayflush-mount thermostat — Offers same features as the 7-day programmable thermostat and includes locking coverplate with tamper proof screws, flush to wall mount, holiday/vacation programming, set point limiting, dual point with adjustable deadband, O or B termi- nal, and optional wall or duct-mounted remote sensor.

Programmable 5-day thermostat — Offers 2-stage heat, 2-stage cool, auto changeover, 5-minute built-in compres- sor protection, locking cover included, temperature display in degrees F or C, keypad lockout, backlit display, 5-1-1 programming, O or B terminal, dual set point with adjust- able deadband, configurable display, self-prompting pro- gram, 4 settings per day.

Non-programmable thermostat — Offers 2 heat stages, 2 cool stages, auto changeover, 5-minute built in compressor protection, locking cover included, temperature display in degrees F or C, keypad lockout, large display, back-lit dis- play, O or B terminal, dual set point with adjustable dead- band, backplate with terminals.

Aquazone system control panel includes a pre- programmed, easy to use, Carrier Comfort Controller set up for a WSHP system.

Coordinates, monitors, and controls all WSHP units and ancillary equipment including cooling towers, boil- ers, and system pumps.

50RLP model nomenclature is used to customize the panel to control all WSHP system requirements.

Panel can be ordered to include 2, 4, 6, or 8 stages of system heat rejection.

Panel can be ordered to include 2, 4, 6, or 8 stages of system heat addition.

Panel can be ordered with unique WSHP zone operation capabilities for stand alone systems (i.e., non-communicating) to control 10 or 18 zones of WSHP units.

Panel can be ordered to control variable frequency cool- ing tower fan operation.

System pumping operation can be configured for start/ stop, lead/lag, or variable frequency pump operation.

Direct Digital Control compatible using the Carrier Comfort Network (CCN) and WSHP units utilizing PremierLink CCN controllers.

Fire-rated hoses are 2 ft long and have a fixed MPT on one end and a swivel with an adapter on the other end. Hose kits are provided with both a supply and return hose and can be either stainless steel or galvanized. Five sizes are available (1/2, 3/4, 1, 11/4, 11/2 in.).

Ball valves (brass body) used for shutoff and balancing water flow. Available with memory, memory stop, and pressure temperature ports. UL-listed brass body, ball and stem type with Teflon seats and seals. Five sizes are avail- able (1/2, 3/4, 1, 11/4, 11/2 in.).

Y strainers (bronze body) are “Y” type strainers with

a

brass cap. Maximum operating pressure rating

of

450 psi. Strainer screen made of stainless steel. Available with blow down valves. Five sizes are available (1/2, 3/4, 1, 11/4, 11/2 in.).

Solenoid valves (brass body) offer 3.5 watt coil, 24 volt, 50/60 Hz, 740 amps inrush, .312 amps holding. Slow operation for quiet system application. Five sizes are available (1/2, 3/4, 1, 11/4, 11/2 in.).

Hose kit assemblies provide all the necessary compo- nents to hook up a water-side system. Supply hose includes a ported ball valve with pressure temperature (P/T) plug ports, flexible stainless steel hose with swivel and nipple. Return hose includes a ball valve, preset auto- matic balancing valve (gpm) with two P/T ports, flexible stainless steel hose with a swivel and nipple, balancing valve, and low-pressure drop water control valve.

Remote sensors are available for Aquazone flush mount thermostats. Sensors are available for wall (wired and wire- less) or duct mounted applications.

PremierLink™ accessories are available to provide a fully integrated WSHP DDC system. Accessories include supply air temperature sensors (with override and/or set- point adjustment), communicating room sensors, CO2 sen- sors (for use in demand control ventilation), and linkage thermostats (to control multiple units from one thermostat).

7

Image 7
Contents Operating efficiency Features/BenefitsTable of contents Features/Benefits Q L 0 7 S a E C 1 0 1 a a Model number nomenclaturePhysical data ARI/ISO 13256-1 capacity ratingsFactory-installed options Options and accessories50KQL Control Options Table Field-installed accessoriesPremierlink Communicating Control Carrier Aquazone Thermostats50KQL Bottom Return Cabinet Dimensions Right Hand Piping DimensionsRear View Access Damper OP Ening 50KQL Bottom Return Cabinet Dimensions Left Hand PipingRear Access 50KQL Front Return Cabinet Dimensions Right Hand PipingRear Access Rear View 50KQL Front Return Cabinet Dimensions Left Hand Piping50KQL Chassis Dimensions Size 07, 09, 12, 15 Selection procedure with 50KQL12 example Page 50KQL07 Nominal Airflow 240 CFM Performance data110 50KQL09 Nominal Airflow 300 CFM12.2 12.350KQL12 Nominal Airflow 350 CFM 17.6 13.8 50KQL15 Nominal Airflow 400 CFM13.9 10.4 17.6 15.1 50KQL19 Nominal Airflow 460 CFM16.7 11.5 21.1 Correction Factors Airflow Correction Factors Entering AIRGround loop systems Application dataWater loop system Ground water systemsWater Quality Guidelines Condensate drainageWater conditioning Acoustical designStarting conditions Wshp sound controlConsole units Operating limitsManual Changeover with Complete C Controller Typical wiring schematicsCB* Note Manual Changeover with Deluxe D ControllerHigh FAN Automatic Changeover with Complete C ControllerUMT Automatic Changeover with Deluxe D ControllerREMOTE-MOUNTED Thermostat with Complete C Controller Transformer Water Valve Field Line Voltage WiringREMOTE-MOUNTED Thermostat with Deluxe D Controller Premierlink Controller Applications with Deluxe D Control Supply Air Temperature SensorSpace Temperature Sensor Premierlink Controller Applications with Complete C Control50KQL Piping Detail Typical pipingConsole Water Source Heat Pumps Guide specificationsGuide specifications Page Carrier Corporation Syracuse, New York