Carrier 50KQL-1PD Premierlink Controller Applications with Complete C Control, Control Relay

Page 31

PREMIERLINK™ CONTROLLER APPLICATIONS WITH COMPLETE C CONTROL

 

LEGEND

CR —

Control Relay

LWT —

Leaving Water Temperature Sensor

SAT —

Supply Air Temperature Sensor

SPT —

Space Temperature Sensor

NOTE: Reversing valve is on in Cooling mode.

PWR

J6J5

PREMIER

LINK

PWR

HS1/EXH/RVS

CR

CMP1

FAN

J1 J8

J4

COMPLETE

C

CONTROL

Y

W

CR

O

G

R

C

AL1

AL2

A

S

S

L

CMPSAFE

 

P

A

W

 

T

T

T

 

PREMIERLINK CONTROLLER APPLICATIONS WITH DELUXE D CONTROL

PREMIER

LINK

PWR

 

 

HS2

 

 

HS1

 

LEGEND

CMP2

LWT — Leaving Water Temperature Sensor

 

SAT — Supply Air Temperature Sensor

 

SPT — Space Temperature Sensor

 

NOTE: Reversing valve is on in Cooling mode.

CMP1

 

 

FAN

 

 

J8

 

PWR

J1

J6

J5

J4

S

S

L

CMPSAFE

 

P

A

W

 

T

T

T

 

DELUXE

D

CONTROL

Y1

Y2

W1

O/W2

G

R

C

AL1

31

Image 31
Contents Operating efficiency Features/BenefitsTable of contents Features/Benefits Q L 0 7 S a E C 1 0 1 a a Model number nomenclaturePhysical data ARI/ISO 13256-1 capacity ratingsFactory-installed options Options and accessories50KQL Control Options Table Field-installed accessoriesPremierlink Communicating Control Carrier Aquazone Thermostats50KQL Bottom Return Cabinet Dimensions Right Hand Piping DimensionsRear View Access Damper OP Ening 50KQL Bottom Return Cabinet Dimensions Left Hand PipingRear Access 50KQL Front Return Cabinet Dimensions Right Hand PipingRear Access Rear View 50KQL Front Return Cabinet Dimensions Left Hand Piping50KQL Chassis Dimensions Size 07, 09, 12, 15 Selection procedure with 50KQL12 example Page 50KQL07 Nominal Airflow 240 CFM Performance data110 50KQL09 Nominal Airflow 300 CFM12.2 12.350KQL12 Nominal Airflow 350 CFM 17.6 13.8 50KQL15 Nominal Airflow 400 CFM13.9 10.4 17.6 15.1 50KQL19 Nominal Airflow 460 CFM16.7 11.5 21.1 Correction Factors Airflow Correction Factors Entering AIRGround loop systems Application dataWater loop system Ground water systemsWater Quality Guidelines Condensate drainageWater conditioning Acoustical designStarting conditions Wshp sound controlConsole units Operating limitsManual Changeover with Complete C Controller Typical wiring schematicsCB* Note Manual Changeover with Deluxe D ControllerHigh FAN Automatic Changeover with Complete C ControllerUMT Automatic Changeover with Deluxe D ControllerREMOTE-MOUNTED Thermostat with Complete C Controller Transformer Water Valve Field Line Voltage WiringREMOTE-MOUNTED Thermostat with Deluxe D Controller Premierlink Controller Applications with Deluxe D Control Supply Air Temperature SensorSpace Temperature Sensor Premierlink Controller Applications with Complete C Control50KQL Piping Detail Typical pipingConsole Water Source Heat Pumps Guide specificationsGuide specifications Page Carrier Corporation Syracuse, New York