Carrier 50KQL-1PD manual 50KQL Front Return Cabinet Dimensions Right Hand Piping, Rear Access

Page 11

50KQL FRONT RETURN CABINET DIMENSIONS — RIGHT HAND PIPING

21.0

(533)

16

(406)

Control Access Door

FRONT VIEW

43.7 (1110)

48.0

(1219)

Filter located behind return

air grille and requires removal of cabinet front for access.

48.0

(1219)

5Discharge

(127)Air

30°

SIDE

VIEW

7.9Air

(201)Inlet

12.0

(305)

3.5

(88.9)

21.0

(533)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12.0

 

 

 

BOTTOM VIEW

 

 

 

 

 

 

 

 

 

 

 

 

 

(305)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 (25)

 

4.5

 

(114)

1 (25)

REAR VIEW

20.0

(508)

REAR

ACCESS

48.0

(1219)

R.H. Pipe &

Electric Area

21.0

(533)

NOTES:

1.All Notes:dimensions are shown in inches. Dimensions in parentheses are in millimeters.

2.Optional1. All dimensiautoflonsw valve,are shownmotorizedin inches.waterDimensionsvalve andin parenthesesdisconnectareboxin millimeters.are shown.

2. Optional autoflow valve, motorized water valve and disconnect box are shown.

11

Image 11
Contents Operating efficiency Features/BenefitsTable of contents Features/Benefits Q L 0 7 S a E C 1 0 1 a a Model number nomenclaturePhysical data ARI/ISO 13256-1 capacity ratingsFactory-installed options Options and accessories50KQL Control Options Table Field-installed accessoriesPremierlink Communicating Control Carrier Aquazone Thermostats50KQL Bottom Return Cabinet Dimensions Right Hand Piping DimensionsRear View Access Damper OP Ening 50KQL Bottom Return Cabinet Dimensions Left Hand PipingRear Access 50KQL Front Return Cabinet Dimensions Right Hand PipingRear Access Rear View 50KQL Front Return Cabinet Dimensions Left Hand Piping50KQL Chassis Dimensions Size 07, 09, 12, 15 Selection procedure with 50KQL12 example Page 50KQL07 Nominal Airflow 240 CFM Performance data110 50KQL09 Nominal Airflow 300 CFM12.2 12.350KQL12 Nominal Airflow 350 CFM 13.9 10.4 17.6 50KQL15 Nominal Airflow 400 CFM17.6 13.8 16.7 11.5 21.1 50KQL19 Nominal Airflow 460 CFM15.1 Correction Factors Airflow Correction Factors Entering AIRGround loop systems Application dataWater loop system Ground water systemsWater Quality Guidelines Condensate drainageWater conditioning Acoustical designStarting conditions Wshp sound controlConsole units Operating limitsManual Changeover with Complete C Controller Typical wiring schematicsCB* Note Manual Changeover with Deluxe D ControllerHigh FAN Automatic Changeover with Complete C ControllerUMT Automatic Changeover with Deluxe D ControllerREMOTE-MOUNTED Thermostat with Complete C Controller Transformer Water Valve Field Line Voltage WiringREMOTE-MOUNTED Thermostat with Deluxe D Controller Premierlink Controller Applications with Deluxe D Control Supply Air Temperature SensorSpace Temperature Sensor Premierlink Controller Applications with Complete C Control50KQL Piping Detail Typical pipingConsole Water Source Heat Pumps Guide specificationsGuide specifications Page Carrier Corporation Syracuse, New York