Carrier 50KQL-1PD manual Model number nomenclature, Q L 0 7 S a E C 1 0 1 a a

Page 4

Model number nomenclature

5 0 K Q L 0 7 S A E C 1 0 1 A A

Aquazone™ High-Efficiency R-22 Water Source Heat Pump 50KQL – Console Unit

Size – Nominal Capacity (Tons)

07

1/2

 

 

 

 

09

3/4

 

 

 

 

12

1

 

 

 

 

 

15

1 1/4

 

 

 

 

19

1 1/2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water Circuit Options

 

 

 

Connection Type

 

Valve Option

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

Sweat

 

2-Way Water Control Valve

 

 

 

B

Sweat

 

Autoflow Regulator, 2.25 gpm/ton

 

 

 

C

Sweat

 

Autoflow Regulator, 3.0 gpm/ton

 

 

 

D

Sweat

 

2-Way Water Control Valve with

 

 

 

E

 

 

 

Autoflow Regulator, 2.25 gpm/ton

 

 

 

Sweat

 

2-WayWater Control Valve with

 

 

 

F

 

 

 

Autoflow Regulator, 3.0 gpm/ton

 

 

 

FPT

 

None

 

 

 

G

FPT

 

2-Way Water Control Valve

 

 

 

H

FPT

 

Autoflow Regulator, 2.25 gpm/ton

 

 

 

J

FPT

 

Autoflow Regulator, 3.0 gpm/ton

 

 

 

K

FPT

 

2-Way Water Control Valve with

 

 

 

L

 

 

 

Autoflow Regulator, 2.25 gpm/ton

 

 

 

FPT

 

2-Way Water Control Valve with

 

 

 

M

 

 

Autoflow Regulator, 3.0 gpm/ton

 

 

 

MPT

 

None

 

 

 

N

MPT

 

2-Way Water Control Valve

 

 

 

P

MPT

 

Autoflow Regulator, 2.25 gpm/ton

 

 

 

Q

MPT

 

Autoflow Regulator, 3.0 gpm/ton

 

 

 

R

MPT

 

2-WayWater Control Valve with

 

 

 

S

 

 

 

Autoflow Regulator, 2.25 gpm/ton

 

 

 

Sweat

 

None

 

 

 

T

MPT

 

2-Way Water Control Valve with

 

 

 

 

 

 

 

Autoflow Regulator, 3.0 gpm/ton

 

 

 

 

 

 

 

 

 

 

Water Supply Orientation*

R – Right Hand

L – Left Hand

Control Options

A– Manual Changeover with Complete C

B– Manual Changeover with Deluxe D

C– Auto Changeover with Complete C

D– Auto Changeover with Deluxe D

P – PremierLink™ DDC Control†

R– Remote Thermostat with Complete C

S– Remote Thermostat with Deluxe D

*Right and left hand orientation is determined by looking at front of unit. * Right and left hand orientation is determined by looking at front of unit. †Available with Complete C only.

For these options, unit must be hard wired (digit 15 must be “A”). **20A plug and cord not available for 265V units.

††Sizes 07,09,12 only.

Power Termination

A Field-Connected Hard Wired

B – 20A Plug and Cord**

D – Disconnect switch, 15A fuse

F – Disconnect switch, non-fused

H – 20A Plug, Cord, Receptacle,

Disconnect Switch, 15A Fuse

K – 20A Plug, Cord, Disconnect

Switch, No Fuse

Packaging

1 – Domestic

Revision Code

0 – Current revision

Power Supply

1 115V-1 Ph-60 Hz††

3 208/230V-1 Ph-60 Hz

4 265V-1 Ph-60 Hz**

Heat Exchanger and Operating Range

C – Copper heat exchanger, standard range (60 to 95 F)

E – Copper heat exchanger, extended range (20 to 110 F) F – Cupronickel heat exchanger, extended range

(20 to 110 F)

N – Cupronickel heat exchanger, standard range (60 to 95 F)

Cabinet, Subbase and Mute Package Options

Std

Mute

Cabinet

Subbase

A

T

Bottom return

3 in. Subbase

B

U

Bottom return

3 in. Subbase with

 

 

 

Motorized Damper

C

V

Bottom return

5 in. Subbase with

 

 

 

Motorized Damper

D

W

Bottom return

NO BASE

E

Y

Bottom return

3 in. Subbase

 

 

Locking control door

 

F

Z

Bottom return

3 in. Subbase with

 

 

Locking control door

Motorized Damper

G

1

Bottom return

5 in. Subbase with

 

 

Locking control door

Motorized Damper

H

2

Bottom return

NO BASE

 

 

Locking control door

 

J

3

Front return

NO BASE

K

4

Front return

NO BASE

 

 

Locking control door

 

L

5

NO CABINET

3 in. Subbase

M

6

NO CABINET

3 in. Subbase with

 

 

 

Motorized Damper

N

7

NO CABINET

5 in. Subbase with

 

 

 

Motorized Damper

P

8

NO CABINET

NO BASE

Q

9

NO CABINET

5 in. Subbase

R

0

Bottom return

5 in. Subbase

S

O

Bottom return

5 in. Subbase

 

 

Locking control door

 

 

 

 

 

4

Image 4
Contents Features/Benefits Operating efficiencyTable of contents Features/Benefits Model number nomenclature Q L 0 7 S a E C 1 0 1 a aARI/ISO 13256-1 capacity ratings Physical dataOptions and accessories Factory-installed optionsField-installed accessories 50KQL Control Options TableCarrier Aquazone Thermostats Premierlink Communicating ControlDimensions 50KQL Bottom Return Cabinet Dimensions Right Hand Piping50KQL Bottom Return Cabinet Dimensions Left Hand Piping Rear View Access Damper OP Ening50KQL Front Return Cabinet Dimensions Right Hand Piping Rear Access50KQL Front Return Cabinet Dimensions Left Hand Piping Rear Access Rear View50KQL Chassis Dimensions Size 07, 09, 12, 15 Selection procedure with 50KQL12 example Page Performance data 50KQL07 Nominal Airflow 240 CFM50KQL09 Nominal Airflow 300 CFM 12.212.3 11050KQL12 Nominal Airflow 350 CFM 17.6 13.8 50KQL15 Nominal Airflow 400 CFM13.9 10.4 17.6 15.1 50KQL19 Nominal Airflow 460 CFM16.7 11.5 21.1 Correction Factors Entering AIR Correction Factors AirflowApplication data Water loop systemGround water systems Ground loop systemsCondensate drainage Water conditioningAcoustical design Water Quality GuidelinesWshp sound control Console unitsOperating limits Starting conditionsTypical wiring schematics Manual Changeover with Complete C ControllerManual Changeover with Deluxe D Controller CB* NoteAutomatic Changeover with Complete C Controller High FANAutomatic Changeover with Deluxe D Controller UMTTransformer Water Valve Field Line Voltage Wiring REMOTE-MOUNTED Thermostat with Complete C ControllerREMOTE-MOUNTED Thermostat with Deluxe D Controller Supply Air Temperature Sensor Space Temperature SensorPremierlink Controller Applications with Complete C Control Premierlink Controller Applications with Deluxe D ControlTypical piping 50KQL Piping DetailGuide specifications Console Water Source Heat PumpsGuide specifications Page Carrier Corporation Syracuse, New York