Gas connection GB Cat: II 2H3+

The gas supply must use the nearest gas inlet pipe which is located at the left or the right hand side at the rear of the appliance (figs. 35, 37).

The hose should also be connected in such away that it does not touch the floor.

To screw the connecting tube operate with two spanners (fig. 36).

The unused end inlet pipe must be closed with the plug interposing the gasket.

After connecting to the mains, check that the coupling are correctly sealed, using soapy solution, but never a flame.

Left gas

inlet pipeRight gas inlet pipe

Fig. 36

Plug

1/2” BSP (male)

Fig. 35

36

Image 36
Contents Dual fuel Cookers CDA Contents Introduction Assembling the backguardFeatures and technical data Gas burnersControl panel Control Panel Controls descriptionElectronic programmer Electronic timer Altering the audible signalElectronic clock fig Normal cooking without the use of the programmerAutomatic oven cooking Semi-automatic cooking How to use the hob burners Hob burnersElectric ignition Lighting of the hob burnersChoice of burner Correct use of triple-ring burnerHow to use the Multifunction oven General featuresOperating principles Oven light Traditional convection cookingGrilling Defrosting frozen foodsHot air cooking Ventilated grill cooking Convection cooking with ventilationSterilization RegenerationSimultaneous cooking of different foods Grilling and au gratin RoastingUse of the grill Important notes For your safety Do’s and do not’sDo’s and do not’s Care and maintenance Flexible tubeEnamelled parts Burners Triple ring burnerRemoval of the inner glass door panel Storage compartmentInside of oven Assembling and dismantling of the side runner framesOven tray Door assembly Removing the oven doorFor Installer Location Fitting the adjustable feet Levelling the cooker Stability bracket Provison for ventilation Gas installation Important NoteInstallation to Natural Gas Gas connectionPlug 200 mm 700 mm Injectors replacement of top burners Conversion to Natural Gas or to LPGAdjusting of the minimum of the top burners Lubrication of the gas taps Table for the choice of the injectorsElectrical installation Connecting feeder cableFeeder cable section Appliance servicing Guarantee Limit of CoverRC 9000 .. cookers