CDA RC 9000 Lubrication of the gas taps, Table for the choice of the injectors

Page 40

Table for the choice of the injectors

GB

 

 

 

 

 

 

Cat: II 2H3+

 

Nominal

Reduced

G 30 - 28-30 mbar

 

 

 

G 20

BURNERS

G 31 - 37 mbar

 

 

20 mbar

 

Power

Power

 

 

 

 

 

 

 

 

By-pass

Ø injector

By-pass

 

Ø injector

 

[kW]

[kW]

 

 

[1/100 mm]

[1/100 mm]

[1/100 mm]

 

[1/100 mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary (A)

1,00

0,30

27

50

 

 

 

 

72 (X)

 

adjustable

 

 

 

 

 

 

 

 

 

 

 

Semi-rapid (SR)

1,75

0,45

32

65

 

 

 

97 (Z)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rapid (R)

3,00

0,75

42

85

 

 

 

 

115 (Y)

 

 

 

 

 

 

 

 

 

 

Triple-ring (TR)

3,50

1,50

65

95

 

 

 

 

135 (T)

 

 

 

 

 

 

 

 

 

 

INCREASE OF AIR NECESSARY FOR GAS COMBUSTION (2 m3/h x kW)

BURNERS

Air necessary for combustion [m3/h]

Auxiliary (A)

2,00

 

 

Semi-rapid (SR)

3,50

 

 

Rapid (R)

6,00

 

 

Triple-ring (TR)

7,00

 

 

Lubrication of the gas taps

The operations must be executed by a qualified technician.

IMPORTANT

All intervention regarding installation maintenance and conversion of the appliance must be fulfilled with original factory parts.

The manufacturer declines any liability resulting from the non-compliance of this obligation.

40

Image 40
Contents Dual fuel Cookers CDA Contents Introduction Assembling the backguardFeatures and technical data Gas burnersControl panel Control Panel Controls descriptionElectronic programmer Electronic timer Altering the audible signalElectronic clock fig Normal cooking without the use of the programmerAutomatic oven cooking Semi-automatic cooking How to use the hob burners Hob burnersElectric ignition Lighting of the hob burnersChoice of burner Correct use of triple-ring burnerGeneral features How to use the Multifunction ovenOperating principles Oven light Traditional convection cookingDefrosting frozen foods GrillingHot air cooking Ventilated grill cooking Convection cooking with ventilationRegeneration SterilizationSimultaneous cooking of different foods Roasting Grilling and au gratinUse of the grill Important notes Do’s and do not’s For your safetyDo’s and do not’s Care and maintenance Flexible tubeEnamelled parts Burners Triple ring burnerRemoval of the inner glass door panel Storage compartmentInside of oven Assembling and dismantling of the side runner framesOven tray Door assembly Removing the oven doorFor Installer Location Fitting the adjustable feet Levelling the cooker Stability bracket Provison for ventilation Gas installation Important NoteInstallation to Natural Gas Gas connectionPlug 200 mm 700 mm Injectors replacement of top burners Conversion to Natural Gas or to LPGAdjusting of the minimum of the top burners Lubrication of the gas taps Table for the choice of the injectorsConnecting feeder cable Electrical installationFeeder cable section Appliance servicing Guarantee Limit of CoverRC 9000 .. cookers