Henny Penny OEA, OFG, OFE If Shortening Flow is Slow from, FAUCET, IT’S Possible That the Filter

Page 15

Model OFE/OFG/OEA/OGA-341, 342

3-9. FILTERING OF

6.

Rinse the frypot as follows:

SHORTENING

 

a.

Close the drain valve.

(Continued)

 

b.

Position return line over empty frypot. Figure 3-8.

 

 

c.

Move the pump switch to the pump position.

 

 

d.

Fill the frypot 1/3 full, then turn off pump.

 

 

e.

Wash down and scrub the sides of the frypot

 

 

 

with the brushes.

 

 

f.

After the sides and bottom are cleaned, open the

 

 

 

drain valve.

 

7. Close drain valve and pump all of the shortening out of

 

 

the filter drain pan and back into the frypot.

Figure 3-8

 

 

 

 

 

IF SHORTENING FLOW IS SLOW FROM THE

 

 

FAUCET, IT’S POSSIBLE THAT THE FILTER

 

 

CONNECTION AT THE UNION ON THE

 

 

FILTER TUBE IS NOT TIGHTENED

 

 

PROPERLY. IF SO, TURN OFF THE PUMP AND

 

 

WEAR ROTECTIVE GLOVES OR CLOTH

 

 

WHEN TIGHTENING THE UNION. THIS

 

 

UNION WILL BE HOT. SEVERE BURNS

 

 

COULD RESULT.

 

8.

When the pump is pumping air only, move the pump

 

 

switch from on to off.

 

9.

Check the level of the shortening in the frypot. Add

 

 

fresh shortening if necessary, until it reaches the top

 

 

level indicator line on the rear wall of the frypot.

406

3-15

Image 15
Contents Operating Components Reference Figure C1000 ControlsDescription Function Model OFE/OFG/OEA/OGA-341 408 Button Controls Operating ControlsButton Controls Model OFE/OFG/OEA/OGA-341 903 Filling or Adding Shortening C1000 Operations and Procedures C1000 Programmng Instructions C1000 Operations ProceduresTimer Programming Set-Point Temperature ProgrammingC1000 Special Programming Model OFE/OFG/OEA/OGA-341 Button Controls/Autolift Basic Operations ProceduresWhen Filter Lockout , then YOU *MUST Basic Operations and Procedures907 Shortening FilteringConnection AT the Union on When Tightening the UNION. thisIf Shortening Flow is Slow from FAUCET, IT’S Possible That the FilterFiltering of Shortening Model OFE/OFG/OEA/OGA-341 Frypots CleaningChanging the Filter EnvelopeFilter drain under the fryer, leaving out the filter screen Filter pan using the shortening shuttle. Then installAssembly Close the drain valve. Discard the shorteningCLEAN-OUT Mode Lighting and Shutdown of the Burners Procedure Frequency