3-4. C1000 OPERATIONS AND PROCEDURES

408

Model OFE/OFG/OEA/OGA-341, 342

The Computron 1000 controls are available on both split electronic controls frypot and full frypot fryers. The following is a brief description of the operating procedures for fryers with these controls.

1.Be sure the drain valve is in the closed position.

2.Place basket support inside of frypot.

3.Make sure frypot is filled with shortening to the proper level.

4.Display shows “OFF” until power switch is turned to the ON position. Display now shows the cook time and the unit automatically goes into the Melt Cycle until the shortening temperature reaches 230°F (110°C). The control then automatically exits the Melt Cycle.

The OFG-320 series open fryer has several safety devices which shuts-down the gas supply when they are activated. The above procedures should be followed to restart the open fryer and if the shut down is repeated, a qualified technician should be notified.

The Melt Cycle may be bypassed, if desired, by pressing

and holding for 3 seconds.

Do not bypass the Melt Cycle unless enough shortening on gas fryers and elements on electric fryers. If Melt Cycle is bypassed before all burner tubes or elements are covered, excessive smoking of the shortening, or a fire will result.

5.Once out of the Melt Cycle, the shortening is heated

until

lights and the cook time is displayed.

Thoroughly stir shortening to stabilize the temperature throughout the frypots.

6.Before loading product into the baskets, lower baskets into the hot shortening to keep the product from sticking to the baskets.

7.Once the shortening temperature has stabilized at the setpoint temperature, lower the basket with product into the frypot.

3-7

Image 7
Contents C1000 Controls Operating Components Reference FigureDescription Function Model OFE/OFG/OEA/OGA-341 408 Button Controls Operating ControlsButton Controls Model OFE/OFG/OEA/OGA-341 903 Filling or Adding Shortening C1000 Operations and Procedures C1000 Programmng Instructions C1000 Operations ProceduresTimer Programming Set-Point Temperature ProgrammingC1000 Special Programming Model OFE/OFG/OEA/OGA-341 Button Controls/Autolift Basic Operations ProceduresWhen Filter Lockout , then YOU *MUST Basic Operations and Procedures907 Shortening FilteringConnection AT the Union on When Tightening the UNION. thisIf Shortening Flow is Slow from FAUCET, IT’S Possible That the FilterFiltering of Shortening Model OFE/OFG/OEA/OGA-341 Frypots CleaningChanging the Filter EnvelopeFilter drain under the fryer, leaving out the filter screen Filter pan using the shortening shuttle. Then installAssembly Close the drain valve. Discard the shorteningCLEAN-OUT Mode Lighting and Shutdown of the Burners Procedure Frequency