Henny Penny manual Model OFE/OFG/OEA/OGA-341

Page 17

Model OFE/OFG/OEA/OGA-341, 342

3-12. CHANGING THE FILTER Change the filter envelope after 10-12 filterings or

ENVELOPEwhenever it becomes clogged with crumbs. Proceed as follows:

The filter union could be hot. Wear protective glove or cloth, or severe burns could result.

Use care to prevent burns caused by splashing of hot shortening.

1.Move the main power switch to the OFF position.

2.Disconnect the filter union and remove the filter drain pan from beneath the frypot.

3.Remove drain pan cover from drain pan and lift the screen assembly from the drain pan.

4.Wipe the shortening and crumbs from the drain pan. Clean the drain pan with soap and water. Thoroughly rinse with hot water.

5.Unthread the suction standpipe from the screen assembly.

6.Remove the crumb catcher and clean thoroughly with soap and water. Rinse thoroughly with hot water.

7.Remove the filter clips and discard the filter envelope.

8.Clean the top and bottom filter screen with soap and water. Rinse thoroughly with hot water.

Be sure that the filter screens, crumb catcher, filter clips and the suction standpipe are thoroughly dry before assembly with the filter envelope or water will dissolve the filter paper.

9.Assemble the top filter screen to the bottom filter screen.

10.Slide the screen into a clean filter envelope.

903

3-17

Image 17
Contents Description Function Operating Components Reference FigureC1000 Controls Model OFE/OFG/OEA/OGA-341 408 Button Controls Operating ControlsButton Controls Model OFE/OFG/OEA/OGA-341 903 Filling or Adding Shortening C1000 Operations and Procedures Timer Programming C1000 Operations ProceduresSet-Point Temperature Programming C1000 Programmng InstructionsC1000 Special Programming Model OFE/OFG/OEA/OGA-341 Button Controls/Autolift Basic Operations ProceduresWhen Filter Lockout , then YOU *MUST Basic Operations and Procedures907 Shortening FilteringIf Shortening Flow is Slow from When Tightening the UNION. thisFAUCET, IT’S Possible That the Filter Connection AT the Union onFiltering of Shortening Model OFE/OFG/OEA/OGA-341 Changing the Filter CleaningEnvelope FrypotsAssembly Filter pan using the shortening shuttle. Then installClose the drain valve. Discard the shortening Filter drain under the fryer, leaving out the filter screenCLEAN-OUT Mode Lighting and Shutdown of the Burners Procedure Frequency