3-6. C1000 SPECIAL PROGRAMMING

1209

Model OFE/OFG/OEA/OGA-341, 342

Special Programming is used to set the items below:

ƒFahrenheit or Celsius

ƒInitialize System

ƒLock or Unlock Controls

ƒFryer Type – Open or Pressure

ƒHeat Source Electric; Gas w/standing pilot; Gas w/electronic ignition; Gas-Induced Draft

ƒVat Type - Split or Full Vat (frypot)

ƒOil Type - Solid or Liquid

1.To enter Special Programming, turn off power switch

(either side). Press and hold

and turn the power

switch back on.

 

2.“SPEC” “PROG” followed by, “DEG” “°F” or “°C”. Use

to choose “°F” or “°C”.

3.Press and “INIT” shows in the display.

Press and hold the right and display shows “In-3”, “In-2”, “In-1” followed by “Init Sys” “DONE DONE”. The controls now are reset to factory parameters, the time set to 0:00 and temperature 190°F or 88°C.

4.Press and “LOCK” or “UNLOCK” shows in the

displays. Use

to choose “LOCK” or

“UNLOCK”.

 

 

 

5. Press

and “FRYR” shows in left display and the right

display should show “OPEN”. Use

to change

from “PRES” to “OPEN” if needed.

 

6.Press and “FRYR” shows in the display. Use

to change the fryer type: “ELEC” for electric models; “GAS” for units with standing pilot; SSI for units with solid state ignition; IDG for units with induced draft gas burners.

7.Press and “VAT” shows in the display. Use

to choose “SPLIT” or FULL” vat (frypot) type.

8.Press and “MELT” and “Solid” or “LIQD” shows in

the displays. Use to choose “Solid”, if using solid shortening, or “LIQD”, if using liquid shortening.

9. Press and hold to exit Special Programming at any time.

3-9

Image 9
Contents Operating Components Reference Figure C1000 ControlsDescription Function Model OFE/OFG/OEA/OGA-341 408 Button Controls Operating ControlsButton Controls Model OFE/OFG/OEA/OGA-341 903 Filling or Adding Shortening C1000 Operations and Procedures Timer Programming C1000 Operations ProceduresSet-Point Temperature Programming C1000 Programmng InstructionsC1000 Special Programming Model OFE/OFG/OEA/OGA-341 Button Controls/Autolift Basic Operations ProceduresWhen Filter Lockout , then YOU *MUST Basic Operations and Procedures907 Shortening FilteringIf Shortening Flow is Slow from When Tightening the UNION. thisFAUCET, IT’S Possible That the Filter Connection AT the Union onFiltering of Shortening Model OFE/OFG/OEA/OGA-341 Changing the Filter CleaningEnvelope FrypotsAssembly Filter pan using the shortening shuttle. Then installClose the drain valve. Discard the shortening Filter drain under the fryer, leaving out the filter screenCLEAN-OUT Mode Lighting and Shutdown of the Burners Procedure Frequency