Henny Penny OEA, OFG, OFE, OGA-341 manual Operating Controls, Button Controls

Page 3

Model OFE/OFG/OEA/OGA-341, 342

3-2.

OPERATING CONTROLS

This section provides operating procedures for the Henny

 

12 BUTTON CONTROLS

Penny 340 series open fryer with 12 button timer controls.

 

 

 

Read sections 1, 2, and 3, and all instructions before

 

 

 

operating the fryer.

 

 

 

Figure 3-2 shows the function of the 12 button timer control.

Fig.

Item

Description

Function

No.

No.

 

 

3-2

1

 

This LED lights when the control calls for heat,

 

 

 

and the burners come on and heat the shortening

3-2

2

Digital Display

Shows the shortening temperature, the timer countdown in

 

 

 

the Cook Cycle, and the selections in the Program Mode;

 

 

 

press the INFO button to display the temperature of the

 

 

 

shortening; if the temperature exceeds 425°F (218°C), the

 

 

 

display reads "E-5", “FRYER TOO HOT”

3-2

3

 

Once the fryer is out of the Melt Mode, this LED

 

 

 

lights, signaling the operator that the shortening temperature

 

 

 

is not at the proper temperature for cooking product

3-2

4

 

This LED lights when the shortening temperature is within 5°

 

 

 

of the setpoint temperature, signaling the operator that the

 

 

 

shortening temperature is at the proper temperature for

 

 

 

cooking product

3-2

5

 

Used to display the current shortening temperature, the

 

 

 

setpoint temperature, as well as cooking performance, and

 

 

 

other information such as, filter use, time of day, etc; in the

 

 

 

Program Mode, it steps back to the previous parameter

3-2

6 & 7

 

Used to adjust the value of the currently displayed setting

 

 

 

in the Program Mode

903

3-3

Image 3
Contents Operating Components Reference Figure C1000 ControlsDescription Function Model OFE/OFG/OEA/OGA-341 408 Button Controls Operating ControlsButton Controls Model OFE/OFG/OEA/OGA-341 903 Filling or Adding Shortening C1000 Operations and Procedures C1000 Programmng Instructions C1000 Operations ProceduresTimer Programming Set-Point Temperature ProgrammingC1000 Special Programming Model OFE/OFG/OEA/OGA-341 Button Controls/Autolift Basic Operations ProceduresWhen Filter Lockout , then YOU *MUST Basic Operations and Procedures907 Shortening FilteringConnection AT the Union on When Tightening the UNION. thisIf Shortening Flow is Slow from FAUCET, IT’S Possible That the FilterFiltering of Shortening Model OFE/OFG/OEA/OGA-341 Frypots CleaningChanging the Filter EnvelopeFilter drain under the fryer, leaving out the filter screen Filter pan using the shortening shuttle. Then installAssembly Close the drain valve. Discard the shorteningCLEAN-OUT Mode Lighting and Shutdown of the Burners Procedure Frequency