Henny Penny OFG, OFE, OGA-341, OEA manual CLEAN-OUT Mode

Page 20

Model OFE/OFG/OEA/OGA-341, 342

3-13. CLEANING

11.

Add approximately 8 ozs. (0.24 liters) of distilled

THE FRYPOT(S)

 

vinegar. Use the Clean-Out Mode (see section 3-14), or

(Continued)

 

bring the solution back up to 195° F (90.5° C).

 

12.

Using a clean brush, scrub the interior of frypot. This

 

 

neutralizes the alkaline left by the cleaning compound.

 

13.

Drain the vinegar rinse water and discard.

 

14.

Rinse down the frypot using clean, hot water.

 

15.

Thoroughly dry the drain pan and the frypot interior.

 

 

Make sure the inside of the frypot, the drain valve

 

 

opening, and all the parts that come in contact with

 

 

new shortening are as dry as possible.

 

 

16.

Replace the clean filter screen assembly in the drain

 

 

pan, replace cover, and install drain pan under fryer.

 

17.

Refill the frypot with fresh shortening.

 

Henny Penny has the following cleaners available:

 

 

Foaming Degreaser - Part no. 12226

 

 

 

PHT Liquid Cleaner - Part no. 12135

 

 

PHT Dry Powder Cleaner - Part no. 12101

 

 

See your local distributor for details.

 

3-14. CLEAN-OUT MODE

When heating the cleaning solution and vinegar solutions,

 

turn the POWER switch to the ON position.

When the fryer

 

starts the Melt Cycle, press and hold

 

 

then

 

 

 

 

 

“CLEAN-OUT ?”, “1=YES 2=NO” shows in display.

 

Press

to start Clean-Out Mode. The fryer displays

“*CLEAN-OUT MODE*” and heats up to a preprogrammed temperature, up to 195˚F (91˚C), then automatically begins a

preset timed countdown. Use the

if necessary, to adjust

the temperature and keep the cleaning solution from boiling over.

Once the timed countdown is complete and display shows “CLEANING DONE”, turn power switch to off position and drain cleaning solution from the frypot.

Refer back to the Cleaning the Frypot procedures for more detailed instructions. See Special Program Modes SP-20 and SP- 21 to preset the temperature and time.

3-20

207

Image 20
Contents Description Function Operating Components Reference FigureC1000 Controls Model OFE/OFG/OEA/OGA-341 408 Operating Controls Button ControlsButton Controls Model OFE/OFG/OEA/OGA-341 903 Filling or Adding Shortening C1000 Operations and Procedures C1000 Operations Procedures Timer ProgrammingSet-Point Temperature Programming C1000 Programmng InstructionsC1000 Special Programming Model OFE/OFG/OEA/OGA-341 Basic Operations Procedures Button Controls/AutoliftBasic Operations and Procedures When Filter Lockout , then YOU *MUST907 Filtering ShorteningWhen Tightening the UNION. this If Shortening Flow is Slow fromFAUCET, IT’S Possible That the Filter Connection AT the Union onFiltering of Shortening Model OFE/OFG/OEA/OGA-341 Cleaning Changing the FilterEnvelope FrypotsFilter pan using the shortening shuttle. Then install AssemblyClose the drain valve. Discard the shortening Filter drain under the fryer, leaving out the filter screenCLEAN-OUT Mode Lighting and Shutdown of the Burners Procedure Frequency