Henny Penny OFG, OFE, OGA-341, OEA manual Filtering of Shortening

Page 16

Model OFE/OFG/OEA/OGA-341, 342

3-9. FILTERING OF SHORTENING (Continued)

About 10 to 12 filterings can be made with one filter paper envelope, depending on:

the quantity and type of product fried and filtered

the type of breading used

the amount of crumbs left inside the filter drain pan; When the filter screen assembly and filter paper become clogged, and the pumping flow slows, clean

the screen assembly and change the filter envelope.

10.To continue cooking, turn the main power switch to the on position. (Remove the element lift tool on electric fryers.)

3-10. FILTER PUMP PROBLEM PREVENTION

Figure 3-9

3-11. FILTER PUMP MOTOR PROTECTOR – MANUAL RESET

To help prevent filter pump problems:

1.Properly install paper envelope over the filter screens. Fold the open end of the envelope, and clamp with retaining clips so that crumbs cannot enter. (See Figure 3-9)

2.Pump shortening, until no shortening is coming from nozzle.

In the event it overheats, the filter pump motor is equipped with a manual reset button located on the rear of the motor. After waiting 5 minutes to allow the motor to cool, press the reset button. It takes some effort to reset the motor.

A screwdriver can be used to help press reset button.

Servicing of the filter pump is done at the side of the unit. If service is required, disconnect the open fryer from the electricaland/or gas power source.

To prevent burns caused by splashing shortening, turn the unit's filter pump switch to the off position before resetting the filter pump motor’s manual reset protection device.

3-16

903

Image 16
Contents C1000 Controls Operating Components Reference FigureDescription Function Model OFE/OFG/OEA/OGA-341 408 Operating Controls Button ControlsButton Controls Model OFE/OFG/OEA/OGA-341 903 Filling or Adding Shortening C1000 Operations and Procedures C1000 Operations Procedures Timer ProgrammingSet-Point Temperature Programming C1000 Programmng InstructionsC1000 Special Programming Model OFE/OFG/OEA/OGA-341 Basic Operations Procedures Button Controls/AutoliftBasic Operations and Procedures When Filter Lockout , then YOU *MUST907 Filtering ShorteningWhen Tightening the UNION. this If Shortening Flow is Slow fromFAUCET, IT’S Possible That the Filter Connection AT the Union onFiltering of Shortening Model OFE/OFG/OEA/OGA-341 Cleaning Changing the FilterEnvelope FrypotsFilter pan using the shortening shuttle. Then install AssemblyClose the drain valve. Discard the shortening Filter drain under the fryer, leaving out the filter screenCLEAN-OUT Mode Lighting and Shutdown of the Burners Procedure Frequency