All fryers are equipped with a drain valve
Remove electrical power supplied to the fryer by unplugging the unit, or turning off the wall circuit breaker or electrical shock could result.
1.The following check should be made to determine if the Drain Switch is defective.
a.) Remove the access panel on the right side of the unit. b.) Remove switch from unit, using 9116” wrench.
c.) Check for continuity across the two outside terminals on the Drain Switch. If circuit is open, the Drain Switch is bad. The circuit should only be opened by pressing on the actuator of the Drain Switch.
2.To replace the Drain Switch, remove the wires from switch.
3.Connect wires to new rain Switch, and reposition switch in unit.
4.Test to seeif drain valve extension rod actuates the switch. NOTE - Listen for CLICK of switch while pulling drain valve extension rod.
The Temperature Probe relays the actual shortening temperature to the control. If it becomes disabled, PROB will show in the display. Also, if the temperature is out of calibra- tion more than loo F or Co, the probe should be replaced as follows:
1. Remove electrical power supplied to the fryer.
Place the Power Switch to the “OFF” position, and unplug the power cord or turn the wall circuit breaker
off or electrical shock could result.
1\.*
I 2. Drain the shortening from the cookpot.