Remove electrical power supplied to the fryer by unplugging the unit, or by turning off the wall circuit breaker or electrical shock could result.
1.If the tube is broken or cracked, the control will open, shut- ting off electrical power. The control cannot be reset.
2.Drain shortening from the cookpot and discard. A substance in the tube could contaminate the shortening.
3.Remove control panel.
4.Loosen small inside screw nut on capillary tube.
5.Remove capillary bulb from bulb holder inside the cookpot.
6.Straighten the capillary tube.
7.Remove larger outside nut that threads into pot wall.
8.Remove the two nuts securing the high limit bracket at the front of the fryer, and remove bracket.
9.Remove the two screws that secure high limit to the high limit bracket.
10.Remove defective control from control panel area.
Il. Insert new control and replace screws.
12.Uncoil capillary line, starting at capillary tube, and insert through cookpot wall.
To avoid electrical shock or other injury, the capillary line must run under and away from all electrical power wires and terminals. The tube must NEVER be in such a position where it could accidentally touch the elec- trical power terminals.
13.Carefully bend the capillary bulb holder on heating elements.
14.Slip capillary bulb into bulb holder located on heating elements. Pull excess capillary line from pot and tighten nut into cookpot wall.