5-22. REMOVAL & CLEANING

 

3.

Clean inside of the elbow with hot water.

 

OF SAFETY VALVE

 

 

 

NOTE

(Continued)

 

 

Turn the relief valve towards the left side of the fryer

 

 

 

when reinstalling relief valve.

 

 

4.

Immerse the safety relief valve in soapy water for 24

 

 

 

hours. Use a 1 to 1 dilution rate. The valve cannot be

 

 

 

disassembled. It is factory preset to open at 14 ½ pounds

 

 

 

of pressure. If it does not open or close, replace it!

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DO NOT DISASSEMBLE OR MODIFY THIS VAVLE!

 

 

 

Tampering with this valve could cause serious injuries and

 

 

 

also voids agency approvals and appliance warranty.

 

 

 

 

 

 

 

5-23. PRESSURE GAUGE

 

 

 

 

 

 

Calibration Steps

 

Recalibrate the pressure gauge if it is out of adjustment.

PRESSURE GAUGE

 

1.

Remove the rim and glass.

 

 

2.

If the indication hand shows a pressure or vacuum reading

 

 

 

when it should stand at “0”, turn the recalibrator screw in

 

 

 

the same direction in the indicating hand is to be moved

 

 

 

until the hand stands at proper “0” position.

 

 

3.

Replace the rim and glass.

Cleaning Steps

 

 

 

 

1.

Remove the gauge and check inside the pipefittings from

 

 

 

dead weight body. Make certain fittings are clean and

 

 

 

open.

 

 

2.

Clean and reinstall the gauge.

5-22

 

 

402

 

Image 22
Contents Page Page Page Page #4 to #5 closed circuit #3 to #2 closed circuit Open Circuit Page 47.9 Heater elements, or Page Temperature Probe ReplacementPanel Henny Penny Complete ControlPressure Regulation Preventive Maintenance Yearly Cleaning and InspectionPage \ \ \.‘@l, $ , $,# Pressure PAD LID Adjustment Volt Page Operating Control Valve Safety Valve Do not Manually Activate the SafetyOperating Control Removal & Cleaning Pressure GaugePage Page