Henny PennyModel 580
|
| 3. | Clean inside of the elbow with hot water. | |||
| ||||||
OF SAFETY VALVE |
|
|
| NOTE | ||
(Continued) |
|
| Turn the relief valve towards the left side of the fryer | |||
|
|
| when reinstalling relief valve. | |||
|
| 4. | Immerse the safety relief valve in soapy water for 24 | |||
|
|
| hours. Use a 1 to 1 dilution rate. The valve cannot be | |||
|
|
| disassembled. It is factory preset to open at 14 ½ pounds | |||
|
|
| of pressure. If it does not open or close, replace it! | |||
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| DO NOT DISASSEMBLE OR MODIFY THIS VAVLE! | |||
|
|
| Tampering with this valve could cause serious injuries and | |||
|
|
| also voids agency approvals and appliance warranty. | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Calibration Steps |
| Recalibrate the pressure gauge if it is out of adjustment. | ||||
PRESSURE GAUGE |
| 1. | Remove the rim and glass. | |||
|
| 2. | If the indication hand shows a pressure or vacuum reading | |||
|
|
| when it should stand at “0”, turn the recalibrator screw in | |||
|
|
| the same direction in the indicating hand is to be moved | |||
|
|
| until the hand stands at proper “0” position. | |||
|
| 3. | Replace the rim and glass. | |||
Cleaning Steps |
|
|
| |||
| 1. | Remove the gauge and check inside the pipefittings from | ||||
|
|
| dead weight body. Make certain fittings are clean and | |||
|
|
| open. | |||
|
| 2. | Clean and reinstall the gauge. | |||
|
| 402 |
|