The following checks, are performed with the wall circuit breaker on, and the Power/Pump Switch in the ower” position. Extreme caution should be taken. ake connections before applying power, take reading, and remove power by unplugging the power cord, or by turning off the wall circuit breaker, before remov-

ing meter leads or electrical shock could result.

5.ith power re-applied and in a heat-up mode, check the power going to both contactor coils. This is to be sure power is going to the contactors.

If no voltage is found going into the coils, the and drain switch for the primary contactor. Section.) For the heat contactor, check wi

If either contactor is defective it must be replaced as follows:

Remove electrical power supplied to the fryer by unplugging power cord or turning off the wall circuit breaker, or electrical shock could result.

emove only those wires directly connected to the contactor being replaced. Label the wires.

2.Remove the two mounting screws on the base plate and remove standard contactor (primary). Proceed to step 5.

3.Remove the two nuts securing the mercury contactor bracket to the base plate and remove bracket.

4.move the two screws securing the mercury contactor the bracket and remove contactor.

5.Install new contactor in reverse order of previous steps. nstall control panel.

econnect power to fryer and test the fryer for proper

Image 7
Contents Page Page Page Page #4 to #5 closed circuit #3 to #2 closed circuit Open Circuit Page 47.9 Heater elements, or Page Replacement Temperature ProbePanel Henny Penny Complete ControlPressure Regulation Yearly Cleaning and Inspection Preventive MaintenancePage \ \ \.‘@l, $ , $,# Pressure PAD LID Adjustment Volt Page Operating Control Valve Safety Valve Do not Manually Activate the SafetyOperating Control Pressure Gauge Removal & CleaningPage Page