Henny Penny 580 manual

Page 14

Check the gasket for any tears or nicks. If the gasket is damaged it needs to be replaced.

Be careful that the lid doesn’t fall down while it is in the upright position, or serious injury could result.

3.Clean the gasket and gasket seat with hot water.

4.Rotate the gasket with the opposite side facing out.

Begin the installation by installing the four corners of the lid gasket, and smoothing the gasket into place from the corners. ,

The Lid Counterweight in the back of the fryer balances the weight of the lid system to allow easier opening and closing of the lid. The weight has two cables attached to it, and weighs about 150 lbs. (67.5 ). One cable is centered on the weight and is the cable being used. The other cable is a safety cable and is off center. In case the main cable becomes loose or broken, the safety cable catches the weight and puts the weight into a bind, not allowing the lid to be opened or closed.

1.Using a 3/8” socket, remove the back shroud of the fryer.

2.With one person holding the weight level, another person locks the lid down.

3.Unthread the broken cable from the weight and the bracket attached to the fryer, and remove broken cable.

4.Thread a 506” nut on each end of the new cable.

5.Screw the new cable into the weight, using a wrench, until it is tight.

Image 14
Contents Page Page Page Page #4 to #5 closed circuit #3 to #2 closed circuit Open Circuit Page 47.9 Heater elements, or Page Temperature Probe ReplacementPressure Regulation Complete ControlPanel Henny Penny Preventive Maintenance Yearly Cleaning and InspectionPage \ \ \.‘@l, $ , $,# Pressure PAD LID Adjustment Volt Page Operating Control Valve Operating Control Do not Manually Activate the SafetySafety Valve Removal & Cleaning Pressure GaugePage Page