Henny Penny 580 manual #4 to #5 closed circuit #3 to #2 closed circuit

Page 5

The Power/Pump Switch is a three way rocker switch with a center “OFF“ position. With the switch in the POWER position the fryer wiil operate. With the switch in the PUMP position the filter pump will operate, but the heating unit will not.

1. Remove Control Panel.

Remove electrical power suppled to the fryer by unplug- ging the unit, or turning off the wall circuit breaker or electrical shock could result.

2.“OFF” Position - should be open circuit anywhere on the switch.

3.“Power” Position Check from:

-5 to -6 closed circuit -1 to -2 closed circuit

4.“Pump” Position Check from:

#4 to #5 closed circuit #3 to #2 closed circuit

Check across the jumpers on the wires of the Power/Pump Switch. These jumpers have resistors and capacitors which may be faulty.

1.With control panel removed and wires off of the switch, push in on tabs on the switch to remove from the panel.

2.Replace with new switch, and reconnect wires to switch following the wiring diagram.

3.Replace the control panel.

Image 5
Contents Page Page Page Page #4 to #5 closed circuit #3 to #2 closed circuit Open Circuit Page 47.9 Heater elements, or Page Replacement Temperature ProbePressure Regulation Complete ControlPanel Henny Penny Yearly Cleaning and Inspection Preventive MaintenancePage \ \ \.‘@l, $ , $,# Pressure PAD LID Adjustment Volt Page Operating Control Valve Operating Control Do not Manually Activate the SafetySafety Valve Pressure Gauge Removal & CleaningPage Page