Henny Penny 580 manual Complete Control, Panel Henny Penny, Pressure Regulation

Page 12

Henny Penny

 

 

 

 

 

Model 580

5-12. COMPLETE CONTROL

 

Should the Control Panel become inoperative, follow these

 

PANEL HENNY PENNY

 

instructions for replacing the board.

 

 

1. Remove electrical power supplied to the fryer.

 

 

Place the Power/Pump Switch in the "OFF" position,

 

 

 

 

 

 

 

the wall circuit

 

 

and unplug the power cord and/ or turn

 

 

breaker off or electrical shock could result.

 

 

2. Remove the two screws securing the Control Panel and

 

 

lift panel up and out.

 

 

3. Unplug the connectors going to the Control Board.

 

 

4. Install a new Control Panel.

 

 

 

 

 

 

 

When plugging

 

 

Control Panel be

 

connectors into new

 

 

sure connectors are put on in the correct manner, such

 

 

as, be sure connector isn't put on backwards.

 

 

 

5-13. PRESSURE REGULATION

 

The Henny Penny Fryer uses pressure as one of the

 

 

components of the cooking process. Once the lid is

 

 

sealed to the cookpot, and the solenoid valve closes, a

 

 

deadweight valve maintains the correct pressure in the

 

 

cookpot.

 

 

The lid has minimal and limited maintenance and

 

 

repair procedures, which are addressed in the

 

 

following sections.

 

 

 

 

 

 

 

5-12

1005

Image 12
Contents Page Page Page Page #4 to #5 closed circuit #3 to #2 closed circuit Open Circuit Page 47.9 Heater elements, or Page Temperature Probe ReplacementComplete Control Panel Henny PennyPressure Regulation Preventive Maintenance Yearly Cleaning and InspectionPage \ \ \.‘@l, $ , $,# Pressure PAD LID Adjustment Volt Page Operating Control Valve Do not Manually Activate the Safety Safety ValveOperating Control Removal & Cleaning Pressure GaugePage Page