Henny Penny 580 manual LID Adjustment

Page 17

Henny Penny

5-18. LID ADJUSTMENT

Model 580

If steam leaks out from around the lid gasket, the pressure pads could be worn or broken. If the pressure pad is worn, but not broken, it can be reversed 180 degrees, and the other end of the

pad used. See Section 5-17.

Other problems could cause the steam to leak, such as a cracked or worn gasket, or gasket not installed properly. Be certain leaking is not caused by too much pressure before making any lid adjustments. Fryer should be operating at 12 psi. Refer to Operating Control Valve section. All these areas should be checked, or serious burns could result.

302

5-17

Image 17
Contents Page Page Page Page #4 to #5 closed circuit #3 to #2 closed circuit Open Circuit Page 47.9 Heater elements, or Page Replacement Temperature ProbePressure Regulation Complete ControlPanel Henny Penny Yearly Cleaning and Inspection Preventive MaintenancePage \ \ \.‘@l, $ , $,# Pressure PAD LID Adjustment Volt Page Operating Control Valve Operating Control Do not Manually Activate the SafetySafety Valve Pressure Gauge Removal & CleaningPage Page