Hoshizaki
M029-897 III. Controls and Adjustments A. Control Switch, B. Control Board
Specifications
Error messages
C. Wiring Diagram
Wire Saddle
Maintenance
RESET Button
H. Quick Adjustments
D. Control Board Settings
Bin Control Cleaning
Refrigerant Recovery
Page 17
Page 16
Page 18
Image 17
Page 16
Page 18
Contents
Stackable Square Cuber Model IM-500SAA
HoshizakiHoshizaki America, Inc
Phone 1-800-233-1940 770 Fax
Complete and detailed explanation of the problem
618 Highway 74 South Peachtree City, GA
Attn Hoshizaki Technical Support Department
CONTENTS
serious injury
Important Safety Information
Indicates a situation which could result in damage to the
appliance or property
WARNING, continued
1. Air-Cooled Model SAA
I. Construction and Water/Refrigeration Circuit Diagram
A. Construction
Water Tank
B. Water/Refrigeration Circuit Diagram
A. Sequence of Operation Flow Chart
II. Sequence of Operation and Service Diagnosis
Shutdown and Restart Sequence Flow Chart
IM Control Board
1. Startup Cycle
B. Sequence of Operation
2. Harvest Cycle
3. Freeze Cycle
4. Shutdown
No Ice Production - Possible Cause
C. Service Diagnosis Table
Long Harvest Cycle
Low Ice Production - Possible Cause
Long Freeze Cycle
Slab Does Not Break Into Separate Cubes - Possible Cause
Cloudy Cubes - Possible Cause
1. Bin Control Check
D. Bin Control Check and Cleaning
2. Bin Control Cleaning
E. Evaporator Thermistor Check
B. Control Board
III. Controls and Adjustments A. Control Switch
Part Number P01873-01 Version 1.3A or Later
1. Control Board Layout
IM Control Board
C. Control Buttons
1. RESET Button
2. SERVICE 1 and SERVICE 2 Buttons
D. Control Board Settings
Freeze Cycle Water Supply Time 2 Partial Drain CB
water supply time 1 CB Setting 12 timer terminates
Freeze Cycle Water Supply Time 1 Partial Drain CB
DO NOT ADJUST
2. Use the SERVICE 1 and SERVICE 2 buttons to move through the list
E. Control Board Information Display
3. Press the RESET button to view the item’s value
4. Press the RESET button to return to list
1.0A, displays as follows
Freeze cycles interrupted by bin control shutdown
example, 655,350 cycles
2. Checking or Changing the Control Board Model Code
F. Control Board Model Code Setting
1. Control Board Replacement
Page
G. Error Codes
1. Dimple Diameter
H. Quick Adjustments
a To increase dimple diameter
b To decrease dimple diameter
Drain Position
2. Ice Clarity
Normal Position
1. Refrigerant Recovery
IV. Refrigeration Circuit and Component Service Information
A. Refrigeration Circuit Service Information
3. Evacuation and Recharge R-404A
2. Brazing
B. Component Service Information
Assembly
Refer to illustration for assembly
J. Pump Motor Assembly
G. Water Pan Assembly
V. Maintenance
2. Drain the water tank
VI. Preparing the Icemaker for Periods of Non-Use
1. Remove the water from the icemaker water supply line
VII. Disposal
1. IM-500SAA
A. Specification Data
VIII. Technical Information
B. Performance Data
1. IM-500SAA
C. Wiring Diagram
Related pages
All Switch page
Switching to aerial view for HTC Surround
On Switch a for Lucent Technologies Release 8.2
Soft switching for Black Box KV120A
Switchboard compatibility for BT BT DIVERSE 5410
Control Switches for Viper 550.2
Cooling fan continues to run after switch-off for Miele KM 5987
Toggle Switch Activation Figure for Sunrise Medical F11
Navigation Back Video Coaxial Switch for Harman-Kardon AVR 354
Using Samsung Smart Switch for Samsung SM-A500FZKUWIN
Samsung Smart Switch használata for Samsung SM-G800FZKAORS
How do I clean the Braun 5414 shaver properly?
View cleaning instructions
Top
Page
Image
Contents