Hoshizaki
M029-897 Freeze cycles interrupted by bin control shutdown, example, 655,350 cycles
Specification
Error codes
C. Wiring Diagram
Wire Saddle
Maintenance
RESET Button
H. Quick Adjustments
D. Control Board Settings
Bin Control Cleaning
Refrigerant Recovery
Page 24
Page 23
Page 25
Image 24
Page 23
Page 25
Contents
HoshizakiHoshizaki America, Inc
Stackable Square Cuber Model IM-500SAA
Complete and detailed explanation of the problem
Phone 1-800-233-1940 770 Fax
618 Highway 74 South Peachtree City, GA
Attn Hoshizaki Technical Support Department
CONTENTS
Important Safety Information
serious injury
Indicates a situation which could result in damage to the
appliance or property
WARNING, continued
I. Construction and Water/Refrigeration Circuit Diagram
A. Construction
1. Air-Cooled Model SAA
B. Water/Refrigeration Circuit Diagram
Water Tank
II. Sequence of Operation and Service Diagnosis
A. Sequence of Operation Flow Chart
Shutdown and Restart Sequence Flow Chart
IM Control Board
B. Sequence of Operation
1. Startup Cycle
2. Harvest Cycle
3. Freeze Cycle
4. Shutdown
C. Service Diagnosis Table
No Ice Production - Possible Cause
Low Ice Production - Possible Cause
Long Harvest Cycle
Long Freeze Cycle
Slab Does Not Break Into Separate Cubes - Possible Cause
Cloudy Cubes - Possible Cause
D. Bin Control Check and Cleaning
1. Bin Control Check
2. Bin Control Cleaning
E. Evaporator Thermistor Check
III. Controls and Adjustments A. Control Switch
B. Control Board
1. Control Board Layout
IM Control Board
Part Number P01873-01 Version 1.3A or Later
1. RESET Button
2. SERVICE 1 and SERVICE 2 Buttons
C. Control Buttons
D. Control Board Settings
water supply time 1 CB Setting 12 timer terminates
Freeze Cycle Water Supply Time 1 Partial Drain CB
Freeze Cycle Water Supply Time 2 Partial Drain CB
Control Board CB Setting Menu
E. Control Board Information Display
2. Use the SERVICE 1 and SERVICE 2 buttons to move through the list
3. Press the RESET button to view the item’s value
4. Press the RESET button to return to list
Freeze cycles interrupted by bin control shutdown
example, 655,350 cycles
1.0A, displays as follows
F. Control Board Model Code Setting
1. Control Board Replacement
2. Checking or Changing the Control Board Model Code
Page
G. Error Codes
H. Quick Adjustments
1. Dimple Diameter
a To increase dimple diameter
b To decrease dimple diameter
2. Ice Clarity
Normal Position
Drain Position
IV. Refrigeration Circuit and Component Service Information
A. Refrigeration Circuit Service Information
1. Refrigerant Recovery
2. Brazing
3. Evacuation and Recharge R-404A
B. Component Service Information
Refer to illustration for assembly
Assembly
J. Pump Motor Assembly
G. Water Pan Assembly
V. Maintenance
VI. Preparing the Icemaker for Periods of Non-Use
1. Remove the water from the icemaker water supply line
2. Drain the water tank
VII. Disposal
A. Specification Data
VIII. Technical Information
1. IM-500SAA
B. Performance Data
C. Wiring Diagram
1. IM-500SAA
Related pages
59TroubleshootingProcedures for Toshiba Qosmio F50
Specifications for Sharp LL-T15A4
Error messages for Panasonic KX-TG3651BX
Appendix Midi Implementation Chart for TC electronic SDN BHD M3000
When this has happened, press Patrone for Sharp UX-B30
Remove Air Motor Install Air Motor for Graco 16T311
Parts List for Hayter Mowers 481A
Programming VCR or DVD Player Using Code Lists con’t for Jasco RM94903
What are the recommended speeds for different diameters of knives on the
Freud Tools table toupie
?
Top
Page
Image
Contents