Hoshizaki M029-897 service manual VIII. Technical Information, A. Specification Data, IM-500SAA

Page 37
VIII. Technical Information

VIII. Technical Information

We reserve the right to make changes in specifications and design without prior notice.

A. Specification Data

1. IM-500SAA

AC SUPPLY VOLTAGE

115/60/1

 

 

 

 

 

AMPERAGE

11.5 A ( 5 Min. Freeze AT 104°F / WT 80°F)

 

MINIMUM CIRCUIT AMPACITY

20 A

 

 

 

 

 

MAXIMUM FUSE SIZE

20 A

 

 

 

 

 

APPROXIMATE ICE PRODUCTION

Ambient

WATER TEMP. (°F)

 

PER 24 HR.

Temp.(°F)

50

 

70

 

90

lbs./day ( kg/day )

70

*500 (227)

 

481 (218)

 

447 (203)

Reference without *marks

80

485 (220)

 

456 (207)

 

417 (189)

 

90

481 (218)

 

*435 (197)

 

397 (180)

SHAPE OF ICE

100

471 (214)

 

426 (193)

 

*363 (165)

Cube Ice

 

 

 

 

 

ICE PRODUCTION PER CYCLE

6.9.lbs. (3.15kg) 140 pcs.

 

 

 

APPROXIMATE STORAGE CAPACITY

N/A

 

 

 

 

 

ELECTRIC & WATER CONSUMPTION

90/70°F

 

 

70/50°F

 

ELECTRIC W (kWH/100 lbs.)

990(5.45)

 

 

920(4.40)

 

 

WATER gal./24HR (gal./100 lbs.)

86(19.8)

 

 

105(21.0)

 

 

CEC/CEE TIER LEVEL

1

 

 

 

 

 

ENERGY STAR

YES

 

 

 

 

 

EXTERIOR DIMENSIONS (WxDxH)

44" x 27.6" x 21.7" (1118 x 700 x 550 mm)

 

EXTERIOR FINISH

Stainless Steel, Galvanized Steel (Rear)

 

WEIGHT

Net 196 lbs. (89 kg), Shipping

220 lbs. (100 kg)

 

CONNECTIONS - ELECTRIC

Permanent-Connection

 

 

 

- WATER SUPPLY

Inlet

1/2" FPT

 

 

 

- DRAIN

Outlet

3/4" FPT

 

 

 

CUBE CONTROL SYSTEM

Thermistor and Timer

 

 

 

HARVESTING CONTROL SYSTEM

Hot Gas, Thermistor and Timer

 

 

 

ICE MAKING WATER CONTROL

Timer Controlled. Overflow Pipe

 

COOLING WATER CONTROL

N/A

 

 

 

 

 

BIN CONTROL SYSTEM

Mechanical Level Switch with Delay

 

COMPRESSOR

Hermetic, Model NT6222GKV

 

 

 

CONDENSER

Air-Cooled, Fin and tube type

 

 

 

EVAPORATOR

Cell type, Copper and Tin dipping

 

REFRIGERANT CONTROL

Thermostatic Expansion Valve

 

 

 

REFRIGERANT CHARGE

R-404A 1lb, 10.5oz (750g)

 

 

 

DESIGN PRESSURE

High 350PSIG, Low 220PSIG

 

 

 

P.C. BOARD CIRCUIT PROTECTION

High Voltage Cut-out ( Internal )

 

 

 

COMPRESSOR PROTECTION

Auto-reset Overload Protector ( Internal )

 

REFRIGERANT CIRCUIT PROTECTION

Auto-reset High Pressure Control Switch

 

LOW WATER PROTECTION

N/A

 

 

 

 

 

ACCESSORIES -SUPPLIED

N/A

 

 

 

 

 

-REQUIRED

Ice Storage Bin

 

 

 

 

 

OPERATING CONDITIONS

VOLTAGE RANGE

 

 

104 - 127 V

 

AMBIENT TEMP.

 

 

45 -100° F

 

WATER SUPPLY TEMP.

 

 

45 - 90° F

 

WATER SUPPLY PRESSURE

 

10 - 113 PSIG

37

Image 37
Contents Stackable Square Cuber Model IM-500SAA HoshizakiHoshizaki America, IncPhone 1-800-233-1940 770 Fax Complete and detailed explanation of the problem618 Highway 74 South Peachtree City, GA Attn Hoshizaki Technical Support DepartmentCONTENTS serious injury Important Safety InformationIndicates a situation which could result in damage to the appliance or propertyWARNING, continued A. Construction I. Construction and Water/Refrigeration Circuit Diagram1. Air-Cooled Model SAA Water Tank B. Water/Refrigeration Circuit DiagramA. Sequence of Operation Flow Chart II. Sequence of Operation and Service DiagnosisShutdown and Restart Sequence Flow Chart IM Control Board1. Startup Cycle B. Sequence of Operation2. Harvest Cycle 3. Freeze Cycle4. Shutdown No Ice Production - Possible Cause C. Service Diagnosis TableLong Harvest Cycle Low Ice Production - Possible CauseLong Freeze Cycle Slab Does Not Break Into Separate Cubes - Possible CauseCloudy Cubes - Possible Cause 1. Bin Control Check D. Bin Control Check and Cleaning2. Bin Control Cleaning E. Evaporator Thermistor Check B. Control Board III. Controls and Adjustments A. Control SwitchIM Control Board 1. Control Board LayoutPart Number P01873-01 Version 1.3A or Later 2. SERVICE 1 and SERVICE 2 Buttons 1. RESET ButtonC. Control Buttons D. Control Board Settings Freeze Cycle Water Supply Time 1 Partial Drain CB water supply time 1 CB Setting 12 timer terminatesFreeze Cycle Water Supply Time 2 Partial Drain CB DO NOT ADJUST 2. Use the SERVICE 1 and SERVICE 2 buttons to move through the list E. Control Board Information Display3. Press the RESET button to view the item’s value 4. Press the RESET button to return to listexample, 655,350 cycles Freeze cycles interrupted by bin control shutdown1.0A, displays as follows 1. Control Board Replacement F. Control Board Model Code Setting2. Checking or Changing the Control Board Model Code Page G. Error Codes 1. Dimple Diameter H. Quick Adjustmentsa To increase dimple diameter b To decrease dimple diameterNormal Position 2. Ice ClarityDrain Position A. Refrigeration Circuit Service Information IV. Refrigeration Circuit and Component Service Information1. Refrigerant Recovery 3. Evacuation and Recharge R-404A 2. BrazingB. Component Service Information Assembly Refer to illustration for assemblyJ. Pump Motor Assembly G. Water Pan AssemblyV. Maintenance 1. Remove the water from the icemaker water supply line VI. Preparing the Icemaker for Periods of Non-Use2. Drain the water tank VII. Disposal VIII. Technical Information A. Specification Data1. IM-500SAA B. Performance Data 1. IM-500SAA C. Wiring Diagram