Control Board (CB) Setting Menu
|
|
|
| |
Category | No. | Item | Range | Default |
Water Tank | 74 | Water Tank Ice Control Lower Temperature | 0 to 40°C | 27 |
Ice Control |
| See CB Setting 70, 71, 72, 74 description above. | (1°C increments) |
|
& Harvest |
| Harvest Cycle Low Temperature Control |
|
|
Cycle Low |
| If control board thermistor temperature at the |
|
|
Temperature |
| beginning of harvest cycle is equal to or less than |
|
|
Control |
| the harvest cycle low temperature control setting, hot |
|
|
|
| gas valve repeatedly energizes for 40 seconds then |
|
|
|
|
|
| |
|
| harvest across the evaporator plate. |
|
|
E. Control Board Information Display
1.With unit on, press and hold the "SERVICE 1" button for 3 seconds. Display changes to "n1".
2.Use the "SERVICE 1" and "SERVICE 2" buttons to move through the list.
3.Press the "RESET" button to view the item’s value.
4.Press the "RESET" button to return to list.
5.Display returns to normal if no buttons are touched for 20 seconds.
Control Board Information Display
|
|
| History Cleared by |
|
|
| Pressing and Holding |
|
|
| SERVICE 1 and |
|
|
| SERVICE 2 Buttons |
|
|
| Simultaneously for |
|
|
| 5 Sec. when Item Value |
No. | Item | Description | is Displayed? |
|
|
|
|
n1 | Freeze Cycle Time | 0 to 99 min. | No |
| During Freeze Cycle: Time since freeze cycle |
|
|
| started. |
|
|
| After Freeze Cycle: Time of previous freeze cycle. |
|
|
|
|
|
|
n2 | Freeze Cycle Completion Rate | 0 to 100% | No |
| During Freeze Cycle: Percent of freeze cycle | 00 = 100% |
|
| completed. |
|
|
| After Freeze Cycle: Percent of previous freeze |
|
|
| cycle completed. |
|
|
|
|
|
|
n3 | Current Evaporator (Cube Control) Thermistor | °C | No |
| Temperature |
|
|
|
|
|
|
n4 | Current Control Board Thermistor Temperature | °C | No |
|
|
|
|
n5 | Water Temperature | "H" if Higher than 48°F | No |
| Temperature at evaporator (cube control) | (9°C) |
|
| thermistor 30 seconds after pump motor | "L" if 48°F (9°C) or |
|
| energized in freeze cycle plus the water | Lower |
|
| temperature correction value (Control Board |
|
|
| Setting 13). |
|
|
n6 | Current Condenser Thermistor Temperature | °C | No |
| Not Applicable to |
|
|
23