Stackable Square Cuber Model IM-500SAA
HoshizakiHoshizaki America, Inc
Phone 1-800-233-1940 770 Fax
Complete and detailed explanation of the problem
618 Highway 74 South Peachtree City, GA
Attn Hoshizaki Technical Support Department
CONTENTS
serious injury
Important Safety Information
Indicates a situation which could result in damage to the
appliance or property
WARNING, continued
A. Construction
I. Construction and Water/Refrigeration Circuit Diagram
1. Air-Cooled Model SAA
Water Tank
B. Water/Refrigeration Circuit Diagram
A. Sequence of Operation Flow Chart
II. Sequence of Operation and Service Diagnosis
Shutdown and Restart Sequence Flow Chart
IM Control Board
1. Startup Cycle
B. Sequence of Operation
2. Harvest Cycle
3. Freeze Cycle
4. Shutdown
No Ice Production - Possible Cause
C. Service Diagnosis Table
Long Harvest Cycle
Low Ice Production - Possible Cause
Long Freeze Cycle
Slab Does Not Break Into Separate Cubes - Possible Cause
Cloudy Cubes - Possible Cause
1. Bin Control Check
D. Bin Control Check and Cleaning
2. Bin Control Cleaning
E. Evaporator Thermistor Check
B. Control Board
III. Controls and Adjustments A. Control Switch
IM Control Board
1. Control Board Layout
Part Number P01873-01 Version 1.3A or Later
2. SERVICE 1 and SERVICE 2 Buttons
1. RESET Button
C. Control Buttons
D. Control Board Settings
Freeze Cycle Water Supply Time 1 Partial Drain CB
water supply time 1 CB Setting 12 timer terminates
Freeze Cycle Water Supply Time 2 Partial Drain CB
DO NOT ADJUST
2. Use the SERVICE 1 and SERVICE 2 buttons to move through the list
E. Control Board Information Display
3. Press the RESET button to view the item’s value
4. Press the RESET button to return to list
example, 655,350 cycles
Freeze cycles interrupted by bin control shutdown
1.0A, displays as follows
1. Control Board Replacement
F. Control Board Model Code Setting
2. Checking or Changing the Control Board Model Code
Page
G. Error Codes
1. Dimple Diameter
H. Quick Adjustments
a To increase dimple diameter
b To decrease dimple diameter
Normal Position
2. Ice Clarity
Drain Position
A. Refrigeration Circuit Service Information
IV. Refrigeration Circuit and Component Service Information
1. Refrigerant Recovery
3. Evacuation and Recharge R-404A
2. Brazing
B. Component Service Information
Assembly
Refer to illustration for assembly
J. Pump Motor Assembly
G. Water Pan Assembly
V. Maintenance
1. Remove the water from the icemaker water supply line
VI. Preparing the Icemaker for Periods of Non-Use
2. Drain the water tank
VII. Disposal
VIII. Technical Information
A. Specification Data
1. IM-500SAA
B. Performance Data
1. IM-500SAA
C. Wiring Diagram
Related pages
Troubleshooting for Maytag W10267631A-SP
KX-TVM50AL/200AL Specifications for Panasonic KX-TVM50AL
Attachment B Orbit II Error Messages for MicroBoards Technology Orbit II
Auto Cook Chart for Panasonic NN-S953
Somewhere Between Real-time and Clear Images for LevelOne FCS-5030
Sequence of INSTALLATIONS, a for A.O. Smith 100 Power Vent DV Series 120
Parts List for Desa LEN) (V)L32(HP
Language code list for Panasonic BTT268
Configuración de Apagar tras for Samsung LS27E510CS/EN
What are the common
IPS signatures Fortigate
users need to know?
Top
Page
Image
Contents