5)Press the "SERVICE 1" button to increase the first digit in the display and the "SERVICE 2" button to increase the second digit. Digits appear in the following order: 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, A, B, C, D, E, F. When a valid model code is displayed, the dot in the bottom right of the display turns on. For IM-500SAA, set model code to "08".

6)When the desired model code is displayed, press the "RESET" button to save the setting. "on" appears in the display.

26

Image 26
Contents HoshizakiHoshizaki America, Inc Stackable Square Cuber Model IM-500SAA618 Highway 74 South Peachtree City, GA Complete and detailed explanation of the problemPhone 1-800-233-1940 770 Fax Attn Hoshizaki Technical Support DepartmentCONTENTS Indicates a situation which could result in damage to the Important Safety Informationserious injury appliance or propertyWARNING, continued 1. Air-Cooled Model SAA I. Construction and Water/Refrigeration Circuit DiagramA. Construction B. Water/Refrigeration Circuit Diagram Water TankShutdown and Restart Sequence Flow Chart II. Sequence of Operation and Service DiagnosisA. Sequence of Operation Flow Chart IM Control Board2. Harvest Cycle B. Sequence of Operation1. Startup Cycle 3. Freeze Cycle4. Shutdown C. Service Diagnosis Table No Ice Production - Possible CauseLong Freeze Cycle Low Ice Production - Possible CauseLong Harvest Cycle Slab Does Not Break Into Separate Cubes - Possible CauseCloudy Cubes - Possible Cause D. Bin Control Check and Cleaning 1. Bin Control Check2. Bin Control Cleaning E. Evaporator Thermistor Check III. Controls and Adjustments A. Control Switch B. Control BoardPart Number P01873-01 Version 1.3A or Later 1. Control Board LayoutIM Control Board C. Control Buttons 1. RESET Button2. SERVICE 1 and SERVICE 2 Buttons D. Control Board Settings Freeze Cycle Water Supply Time 2 Partial Drain CB water supply time 1 CB Setting 12 timer terminatesFreeze Cycle Water Supply Time 1 Partial Drain CB DO NOT ADJUST 3. Press the RESET button to view the item’s value E. Control Board Information Display2. Use the SERVICE 1 and SERVICE 2 buttons to move through the list 4. Press the RESET button to return to list1.0A, displays as follows Freeze cycles interrupted by bin control shutdownexample, 655,350 cycles 2. Checking or Changing the Control Board Model Code F. Control Board Model Code Setting1. Control Board Replacement Page G. Error Codes a To increase dimple diameter H. Quick Adjustments1. Dimple Diameter b To decrease dimple diameterDrain Position 2. Ice ClarityNormal Position 1. Refrigerant Recovery IV. Refrigeration Circuit and Component Service InformationA. Refrigeration Circuit Service Information 2. Brazing 3. Evacuation and Recharge R-404AB. Component Service Information J. Pump Motor Assembly Refer to illustration for assemblyAssembly G. Water Pan AssemblyV. Maintenance 2. Drain the water tank VI. Preparing the Icemaker for Periods of Non-Use1. Remove the water from the icemaker water supply line VII. Disposal 1. IM-500SAA A. Specification DataVIII. Technical Information B. Performance Data C. Wiring Diagram 1. IM-500SAA