Hoshizaki
M029-897 B. Water/Refrigeration Circuit Diagram, Air-Cooled Model SAA, Water Tank
Specs
Error codes
C. Wiring Diagram
Wire Saddle
Maintenance
RESET Button
H. Quick Adjustments
D. Control Board Settings
Bin Control Cleaning
Refrigerant Recovery
Page 7
Page 6
Page 8
Image 7
Page 6
Page 8
Contents
Stackable Square Cuber Model IM-500SAA
HoshizakiHoshizaki America, Inc
Attn Hoshizaki Technical Support Department
Complete and detailed explanation of the problem
Phone 1-800-233-1940 770 Fax
618 Highway 74 South Peachtree City, GA
CONTENTS
appliance or property
Important Safety Information
serious injury
Indicates a situation which could result in damage to the
WARNING, continued
A. Construction
I. Construction and Water/Refrigeration Circuit Diagram
1. Air-Cooled Model SAA
Water Tank
B. Water/Refrigeration Circuit Diagram
IM Control Board
II. Sequence of Operation and Service Diagnosis
A. Sequence of Operation Flow Chart
Shutdown and Restart Sequence Flow Chart
3. Freeze Cycle
B. Sequence of Operation
1. Startup Cycle
2. Harvest Cycle
4. Shutdown
No Ice Production - Possible Cause
C. Service Diagnosis Table
Slab Does Not Break Into Separate Cubes - Possible Cause
Low Ice Production - Possible Cause
Long Harvest Cycle
Long Freeze Cycle
Cloudy Cubes - Possible Cause
1. Bin Control Check
D. Bin Control Check and Cleaning
2. Bin Control Cleaning
E. Evaporator Thermistor Check
B. Control Board
III. Controls and Adjustments A. Control Switch
IM Control Board
1. Control Board Layout
Part Number P01873-01 Version 1.3A or Later
2. SERVICE 1 and SERVICE 2 Buttons
1. RESET Button
C. Control Buttons
D. Control Board Settings
Freeze Cycle Water Supply Time 1 Partial Drain CB
water supply time 1 CB Setting 12 timer terminates
Freeze Cycle Water Supply Time 2 Partial Drain CB
IM-500SAA
4. Press the RESET button to return to list
E. Control Board Information Display
2. Use the SERVICE 1 and SERVICE 2 buttons to move through the list
3. Press the RESET button to view the item’s value
example, 655,350 cycles
Freeze cycles interrupted by bin control shutdown
1.0A, displays as follows
1. Control Board Replacement
F. Control Board Model Code Setting
2. Checking or Changing the Control Board Model Code
Page
G. Error Codes
b To decrease dimple diameter
H. Quick Adjustments
1. Dimple Diameter
a To increase dimple diameter
Normal Position
2. Ice Clarity
Drain Position
A. Refrigeration Circuit Service Information
IV. Refrigeration Circuit and Component Service Information
1. Refrigerant Recovery
3. Evacuation and Recharge R-404A
2. Brazing
B. Component Service Information
G. Water Pan Assembly
Refer to illustration for assembly
Assembly
J. Pump Motor Assembly
V. Maintenance
1. Remove the water from the icemaker water supply line
VI. Preparing the Icemaker for Periods of Non-Use
2. Drain the water tank
VII. Disposal
VIII. Technical Information
A. Specification Data
1. IM-500SAA
B. Performance Data
1. IM-500SAA
C. Wiring Diagram
Related pages
All Diagram page
CustomCool Chart Safety Instructions Operating for GE 200D2600P010
Electrical Schematics VII for Jackson AJ-100CE
−3. Schematic Diagram for Texas Instruments THS4503EVM
Wiring Diagram for Audiovox Car Stereo System
Canadian Englishratingchart for Polaroid FLM-3201
Assembly Diagram Engine for Chicago Electric 94678
Exploded View Diagram FXM-2611C for Polaroid FXM-2611C
Filter Error Flowchart for Frymaster BIGLA30
DCS Privacy Code Chart for Midland Radio GXT750 Series
Setup Diagram for Hawking Technology H2BR4
What are the specifications of the
Generac 10kW generator models
?
Top
Page
Image
Contents