Hoshizaki M029-897 service manual Ice Clarity, Normal Position, Drain Position

Page 29
2.Ice Clarity

3)Press the "SERVICE 2" button to lower freeze cycle termination temperature setting (Control Board Setting 2). Temperature setting lowers in .5°C increments. The "." in the lower, right corner of the display indicates .5°C. Default is -18.5°C. NOTICE! Do not decrease dimple size below 3/16" (5 mm).

4)Once the display returns to "on" (20 seconds), the new setting is saved.

2.Ice Clarity

In hard water conditions, white ice may be produced. In such cases, install a water filter and/or water softener, then follow the instructions below.

1)Move the control switch to the "OFF" position, then turn off the power supply.

2)Remove the front panel.

3)Remove the screw, then move the water tank drain pipe to the drain position. See Fig. 2. Use the screw to secure the water tank drain pipe in the drain position.

4)Turn on the power supply, then move the control switch to the "ICE" position.

5)Press and hold the "RESET" button for 3 seconds. "1" appears in the display.

6)Press the "SERVICE 1" button until "12" appears in the display. Press the "RESET" button. The current icemaking water supply time value flashes in the display. Press the "SERVICE 1" or "SERVICE 2" buttons to change the setting to "60".

7)Press the "RESET" button to save the setting and return to the menu.

8)Using the same procedure as above, change the full/partial drain setting (Control Board Setting 14) from "1" (partial drain) to "0" (full drain).

9)Using the same procedure as above, change the additional icemaking water supply time setting (Control Board Setting 15) to "44".

10)Once the display returns to "on" (20 seconds), the new setting is saved.

11)Replace the front panel in its correct position.

Note: If white ice continues to be an issue, set hard water setting water supply time (Control Board Setting 61) to "15". This results in the inlet water valve energizing for 15 seconds part way through the freeze cycle and diluting the water in the water tank. Do not increase this setting beyond 15 seconds; otherwise, freeze cycle times may become long and bridging may occur in the ice storage bin.

Normal Position

Drain Position

Screw

Water Tank Drain Pipe

Fig. 2

29

Image 29
Contents Stackable Square Cuber Model IM-500SAA HoshizakiHoshizaki America, IncPhone 1-800-233-1940 770 Fax Complete and detailed explanation of the problem618 Highway 74 South Peachtree City, GA Attn Hoshizaki Technical Support DepartmentCONTENTS serious injury Important Safety InformationIndicates a situation which could result in damage to the appliance or propertyWARNING, continued 1. Air-Cooled Model SAA I. Construction and Water/Refrigeration Circuit DiagramA. Construction Water Tank B. Water/Refrigeration Circuit DiagramA. Sequence of Operation Flow Chart II. Sequence of Operation and Service DiagnosisShutdown and Restart Sequence Flow Chart IM Control Board1. Startup Cycle B. Sequence of Operation2. Harvest Cycle 3. Freeze Cycle4. Shutdown No Ice Production - Possible Cause C. Service Diagnosis TableLong Harvest Cycle Low Ice Production - Possible CauseLong Freeze Cycle Slab Does Not Break Into Separate Cubes - Possible CauseCloudy Cubes - Possible Cause 1. Bin Control Check D. Bin Control Check and Cleaning2. Bin Control Cleaning E. Evaporator Thermistor Check B. Control Board III. Controls and Adjustments A. Control SwitchPart Number P01873-01 Version 1.3A or Later 1. Control Board LayoutIM Control Board C. Control Buttons 1. RESET Button2. SERVICE 1 and SERVICE 2 Buttons D. Control Board Settings Freeze Cycle Water Supply Time 2 Partial Drain CB water supply time 1 CB Setting 12 timer terminatesFreeze Cycle Water Supply Time 1 Partial Drain CB DO NOT ADJUST 2. Use the SERVICE 1 and SERVICE 2 buttons to move through the list E. Control Board Information Display3. Press the RESET button to view the item’s value 4. Press the RESET button to return to list1.0A, displays as follows Freeze cycles interrupted by bin control shutdownexample, 655,350 cycles 2. Checking or Changing the Control Board Model Code F. Control Board Model Code Setting1. Control Board Replacement Page G. Error Codes 1. Dimple Diameter H. Quick Adjustmentsa To increase dimple diameter b To decrease dimple diameterDrain Position 2. Ice ClarityNormal Position 1. Refrigerant Recovery IV. Refrigeration Circuit and Component Service InformationA. Refrigeration Circuit Service Information 3. Evacuation and Recharge R-404A 2. BrazingB. Component Service Information Assembly Refer to illustration for assemblyJ. Pump Motor Assembly G. Water Pan AssemblyV. Maintenance 2. Drain the water tank VI. Preparing the Icemaker for Periods of Non-Use1. Remove the water from the icemaker water supply line VII. Disposal 1. IM-500SAA A. Specification DataVIII. Technical Information B. Performance Data 1. IM-500SAA C. Wiring Diagram