HoshizakiHoshizaki America, Inc
Stackable Square Cuber Model IM-500SAA
618 Highway 74 South Peachtree City, GA
Complete and detailed explanation of the problem
Phone 1-800-233-1940 770 Fax
Attn Hoshizaki Technical Support Department
CONTENTS
Indicates a situation which could result in damage to the
Important Safety Information
serious injury
appliance or property
WARNING, continued
1. Air-Cooled Model SAA
I. Construction and Water/Refrigeration Circuit Diagram
A. Construction
B. Water/Refrigeration Circuit Diagram
Water Tank
Shutdown and Restart Sequence Flow Chart
II. Sequence of Operation and Service Diagnosis
A. Sequence of Operation Flow Chart
IM Control Board
2. Harvest Cycle
B. Sequence of Operation
1. Startup Cycle
3. Freeze Cycle
4. Shutdown
C. Service Diagnosis Table
No Ice Production - Possible Cause
Long Freeze Cycle
Low Ice Production - Possible Cause
Long Harvest Cycle
Slab Does Not Break Into Separate Cubes - Possible Cause
Cloudy Cubes - Possible Cause
D. Bin Control Check and Cleaning
1. Bin Control Check
2. Bin Control Cleaning
E. Evaporator Thermistor Check
III. Controls and Adjustments A. Control Switch
B. Control Board
Part Number P01873-01 Version 1.3A or Later
1. Control Board Layout
IM Control Board
C. Control Buttons
1. RESET Button
2. SERVICE 1 and SERVICE 2 Buttons
D. Control Board Settings
Freeze Cycle Water Supply Time 2 Partial Drain CB
water supply time 1 CB Setting 12 timer terminates
Freeze Cycle Water Supply Time 1 Partial Drain CB
DO NOT ADJUST
3. Press the RESET button to view the item’s value
E. Control Board Information Display
2. Use the SERVICE 1 and SERVICE 2 buttons to move through the list
4. Press the RESET button to return to list
1.0A, displays as follows
Freeze cycles interrupted by bin control shutdown
example, 655,350 cycles
2. Checking or Changing the Control Board Model Code
F. Control Board Model Code Setting
1. Control Board Replacement
Page
G. Error Codes
a To increase dimple diameter
H. Quick Adjustments
1. Dimple Diameter
b To decrease dimple diameter
Drain Position
2. Ice Clarity
Normal Position
1. Refrigerant Recovery
IV. Refrigeration Circuit and Component Service Information
A. Refrigeration Circuit Service Information
2. Brazing
3. Evacuation and Recharge R-404A
B. Component Service Information
J. Pump Motor Assembly
Refer to illustration for assembly
Assembly
G. Water Pan Assembly
V. Maintenance
2. Drain the water tank
VI. Preparing the Icemaker for Periods of Non-Use
1. Remove the water from the icemaker water supply line
VII. Disposal
1. IM-500SAA
A. Specification Data
VIII. Technical Information
B. Performance Data
C. Wiring Diagram
1. IM-500SAA
Related pages
All Problem page
Problema Controllo Rimedio for Samsung WAM270/ZF
Solucionar problemas for GE 162D6733P007
Symptom What you should do for Philips 21PT3952
Problemløsning for Samsung UE55H6895SUXXE
Solución de problemas for Dell precision workstation
Problem Causes and Solutions for JBL GX-A602
Follow Instructions to Avoid Interference Problems for Motorola V557
General printing problems for Lexmark 5770
If you have a problem for Whirlpool ET17SCXL
Solutions to Common Problems for Apple 9600
How can I confirm the battery is functioning in the
Dell R820 manual
?
Top
Page
Image
Contents