Hoshizaki M029-897 service manual D. Control Board Settings

Page 20
D. Control Board Settings

D. Control Board Settings

NOTICE

Failure to maintain factory settings may adversely affect performance and warranty coverage. For more information, contact your Hoshizaki Service Center.

1)With "on" in display, press and hold the "RESET" button for 3 seconds. Display changes to "1".

2)Use the "SERVICE 1" and "SERVICE 2" buttons to choose a control board setting.

3)Press the "RESET" button to view the setting’s value. Current value flashes in display.

4)Use the "SERVICE 1" and "SERVICE 2" buttons to change value.

5)Press the "RESET" button to select value. Display returns to control board setting number.

6)Once display returns to "on" (20 seconds), the new setting is saved.

Control Board (CB) Setting Menu

 

 

 

 

IM-500SAA

Category

No.

Item

Range

Default

Basic

1

Harvest Cycle Termination Temperature

2 to 20°C

5

 

 

Temperature to complete harvest cycle.

(1°C increments)

 

 

2

Freeze Cycle Termination Temperature

-5 to -40°C

-18.5

 

 

Integrated with freeze cycle termination time (CB

(0.5°C increments. The

 

 

 

Setting 3) to control length of freeze cycle after

"." in the lower, right

 

 

 

evaporator (cube control) thermistor temperature

corner of the display

 

 

 

drops to 32°F (0°C). To use this setting for dimple

indicates .5°C.)

 

 

 

size adjustment, see "III.H.1. Dimple Diameter."

 

 

 

 

 

 

 

 

3

Freeze Cycle Termination Time

5 to 90 min.

10

 

 

Integrated with freeze cycle termination temperature

(1 min. increments)

 

 

 

(CB Setting 2) to control length of freeze cycle after

 

 

 

 

evaporator (cube control) thermistor temperature

 

 

 

 

drops to 32°F (0°C).

 

 

 

 

 

 

 

 

4

Ambient Temperature Correction Value for Freeze

10 to 50°C

10

 

 

Cycle Termination

(1°C increments)

 

 

 

DO NOT ADJUST

 

 

 

 

 

 

 

 

5

Ambient Temperature Correction Rate for Freeze

10 to 100% (00 = 100)

100

 

 

Cycle Termination

(1% increments)

 

 

 

DO NOT ADJUST

 

 

 

6

Freeze Cycle Backup Timer

45 to 90 min.

45

 

 

Maximum allowed freeze time to prevent possible

(5 min. increments)

 

 

 

freeze-up issues.

 

 

 

 

 

 

 

Water

10

Harvest Cycle Water Supply Time: Water

1 to 99 sec,

95

Supply

 

Temperature 48°F (9°C) or Lower

99 = continuous

 

 

 

When set to "99", inlet water valve energized until

(1 sec. increments)

 

 

 

harvest cycle termination temperature (CB Setting 1)

 

 

 

 

is reached.

 

 

 

 

 

 

 

 

11

Harvest Cycle Water Supply Time: Water

1 to 99 sec,

30

 

 

Temperature Higher Than 48°F (9°C)

99 = continuous

 

 

 

When set to "99", inlet water valve energized until

(1 sec. increments)

 

 

 

harvest cycle termination temperature (CB Setting 1)

 

 

 

 

is reached.

 

 

 

 

 

 

 

20

Image 20
Contents HoshizakiHoshizaki America, Inc Stackable Square Cuber Model IM-500SAAComplete and detailed explanation of the problem Phone 1-800-233-1940 770 Fax618 Highway 74 South Peachtree City, GA Attn Hoshizaki Technical Support DepartmentCONTENTS Important Safety Information serious injuryIndicates a situation which could result in damage to the appliance or propertyWARNING, continued 1. Air-Cooled Model SAA I. Construction and Water/Refrigeration Circuit DiagramA. Construction B. Water/Refrigeration Circuit Diagram Water TankII. Sequence of Operation and Service Diagnosis A. Sequence of Operation Flow ChartShutdown and Restart Sequence Flow Chart IM Control BoardB. Sequence of Operation 1. Startup Cycle2. Harvest Cycle 3. Freeze Cycle4. Shutdown C. Service Diagnosis Table No Ice Production - Possible CauseLow Ice Production - Possible Cause Long Harvest CycleLong Freeze Cycle Slab Does Not Break Into Separate Cubes - Possible CauseCloudy Cubes - Possible Cause D. Bin Control Check and Cleaning 1. Bin Control Check2. Bin Control Cleaning E. Evaporator Thermistor Check III. Controls and Adjustments A. Control Switch B. Control BoardPart Number P01873-01 Version 1.3A or Later 1. Control Board LayoutIM Control Board C. Control Buttons 1. RESET Button2. SERVICE 1 and SERVICE 2 Buttons D. Control Board Settings Freeze Cycle Water Supply Time 2 Partial Drain CB water supply time 1 CB Setting 12 timer terminatesFreeze Cycle Water Supply Time 1 Partial Drain CB Control Board CB Setting Menu E. Control Board Information Display 2. Use the SERVICE 1 and SERVICE 2 buttons to move through the list3. Press the RESET button to view the item’s value 4. Press the RESET button to return to list1.0A, displays as follows Freeze cycles interrupted by bin control shutdownexample, 655,350 cycles 2. Checking or Changing the Control Board Model Code F. Control Board Model Code Setting1. Control Board Replacement Page G. Error Codes H. Quick Adjustments 1. Dimple Diametera To increase dimple diameter b To decrease dimple diameterDrain Position 2. Ice ClarityNormal Position 1. Refrigerant Recovery IV. Refrigeration Circuit and Component Service InformationA. Refrigeration Circuit Service Information 2. Brazing 3. Evacuation and Recharge R-404AB. Component Service Information Refer to illustration for assembly AssemblyJ. Pump Motor Assembly G. Water Pan AssemblyV. Maintenance 2. Drain the water tank VI. Preparing the Icemaker for Periods of Non-Use1. Remove the water from the icemaker water supply line VII. Disposal 1. IM-500SAA A. Specification DataVIII. Technical Information B. Performance Data C. Wiring Diagram 1. IM-500SAA