InSinkErator 1100 Mounting the Tank, Connecting Faucet to Tank, Tank a, Tank B, Both Tanks

Page 7

3

MOUNTING THE TANK

A

Tank must be mounted level to ensure proper operation.

Property Damage: Tank must be located within 16" of faucet and within 30" or less of a standard grounded outlet. DO NOT extend plumbing or electrical lines.

Select a spot under the sink to mount tank vertically within reach of both plumbing and electrical connections. The tank should be within 16" or less of faucet water lines and within 30" or less of a standard grounded outlet.

While holding tank in place on

the spot selected for installation, use a pencil to mark locations for 2 hanging screws.

B

Leave 1/4" for hanging tank.

Mount tank vertically in an area that

allows clearance on the underside of the

tank for drainage, if necessary. DO NOT over tighten screws.

Screws provided are for use in wood studs or cabinets only. Use wall anchors (not supplied) for installation into drywall.

Pre-drill 1/8" pilot holes at marks.

Turn screws into pre-drilled holes, leaving 1/4" exposed.

Hang the tank on the screws.

Tighten the screws with only 1/2 turn clockwise.

CONNECTING FAUCET TO TANK

4 A

 

 

Tank A

(1)

(2)

(3)

Without depressing the gray button,

 

 

 

place the snap-connect fitting at

 

 

 

the end of the blue or copper 1/4"

 

 

 

tube onto the left fitting on the tank,

Tank A

 

 

pushing until it clicks into place. (1)

 

 

Tank B

 

 

 

 

 

 

Insert blue 1/4" tube into quick-

(1)

(3)

(2)

connect fitting at left. (1)

Both Tanks

 

 

 

 

 

 

Slip the flexible white 7/16" tube

Tank B

 

 

over barbed steel fitting and slide

 

 

 

down approximately 1/2". (2)

 

 

 

Slip the clear 5/16" tube over the

 

 

 

smooth plastic fitting and slide down

Property Damage: Pinched or blocked water lines

approximately 1/2". (3)

may cause damage to the dispenser tank.

Check for pinched or crimped tubes.

Property Damage: Check to make sure

Hose clamps are not needed for any

tubes are connected properly and are

pushed down as far as possible.

of the connections.

7

Image 7 Contents
Instant Hot Water Dispenser What YOU Need to GET Started What YOU should Know Before YOU Begin Straighten the copper tubing Unpack dispenser componentsFilter Head Components in this PackagePlug Semi-circular Mounting Plate Hex Tool31⁄8 Preparation37⁄8 Unpack dispenser components Installing the FaucetOn a firm, flat surface, carefully Straighten the copper tubingTank B Connecting Faucet to TankMounting the Tank Tank aScrews provided are for use in wood Installing Filtration SystemTurn on the cold water supply Final Water ConnectionIf Installing only NEW Tank If Installing only NEW FaucetProperty Damage Year warranty excluding replaceable filter cartridge Warranty InformationShut the cold water supply off at the valve Factory temperature pre-set isDisconnect power from unit Care and USEFiltration Information Troubleshooting Manual del usuario LO QUE Usted Debe Saber Antes DE Comenzar Lo que usted verá en el manual de instrucciones Cómo Usar Este Manual DE InstruccionesHexagonal Contenido DE Este PaqueteMínimo requerido del PreparaciónInstalación DEL Grifo Tanque B Montaje DEL TanqueConexión DEL Grifo EN EL Tanque Tanque aInstalación DEL Filtro El agua saldrá fría en un principio Conexión Final DEL AguaDel tanque Para Instalar Sólo UN Grifo NuevoPara Instalar Sólo UN Tanque Nuevo Inserte el tubo azul dentro del accesorioTanques de acero inoxidable Información Sobre LA GarantíaExcluyendo el cartucho del filtro reemplazable Ajuste DEL Termostato Guía Para EL Filtro Y Reemplazo Mantenimiento Y USOInformación DE LA Filtración Identificación Y Solución DE Problemas Manuel du propriétaire CE QUE Vous Devriez Savoir Avant DE Commencer Cuivre Comment Utiliser CE Manuel D’INSTRUCTIONSDans CET Emballage GN1100 37⁄8 10 cm PréparationGN2215 37⁄8 10 cm HC2200 GN2200 37⁄8 10 cm HC1100Sur une surface plane et ferme Installation DU RobinetDéballez les composantes Du distributeurRéservoir B Montage DU RéservoirRaccordement DU Robinet AU Réservoir Réservoir aOu de pincement du tube Installation DU Systéme DE FiltrationDe cuivre plus loin que les 16 po fournis ’eau sera froide au début Connexion Finale DE L’EAUBranchez le réservoir d’eau chaude instantanée Dernier pouce du tube Dommage matérielAvant de raccorder le robinet Ne serrez pas trop l’écrou en laitonRéservoir en acier inoxydable Renseignements SUR LA GarantieRéglage DU Thermostat Soins ET UtilisationInformation DE Filtration Diagnostics 800.558.5700