3
MOUNTING THE TANK
A
Tank must be mounted level to ensure proper operation.
Property Damage: Tank must be located within 16" of faucet and within 30" or less of a standard grounded outlet. DO NOT extend plumbing or electrical lines.
■Select a spot under the sink to mount tank vertically within reach of both plumbing and electrical connections. The tank should be within 16" or less of faucet water lines and within 30" or less of a standard grounded outlet.
■While holding tank in place on
the spot selected for installation, use a pencil to mark locations for 2 hanging screws.
B
Leave 1/4" for hanging tank.
Mount tank vertically in an area that
allows clearance on the underside of the
tank for drainage, if necessary. DO NOT over tighten screws.
Screws provided are for use in wood studs or cabinets only. Use wall anchors (not supplied) for installation into drywall.
■
■Turn screws into
■Hang the tank on the screws.
■Tighten the screws with only 1/2 turn clockwise.
CONNECTING FAUCET TO TANK | ||||
4 A |
|
| Tank A | |
(1) | (2) | (3) | ■ Without depressing the gray button, | |
|
|
| place the | |
|
|
| the end of the blue or copper 1/4" | |
|
|
| tube onto the left fitting on the tank, | |
Tank A |
|
| pushing until it clicks into place. (1) | |
|
| Tank B | ||
|
|
| ||
|
|
| ■ Insert blue 1/4" tube into quick- | |
(1) | (3) | (2) | connect fitting at left. (1) | |
Both Tanks | ||||
|
|
| ||
|
|
| ■ Slip the flexible white 7/16" tube | |
Tank B |
|
| over barbed steel fitting and slide | |
|
|
| down approximately 1/2". (2) | |
|
|
| ■ Slip the clear 5/16" tube over the | |
|
|
| smooth plastic fitting and slide down | |
Property Damage: Pinched or blocked water lines | approximately 1/2". (3) | |||
may cause damage to the dispenser tank. | ■ Check for pinched or crimped tubes. | |||
Property Damage: Check to make sure | ||||
Hose clamps are not needed for any | ||||
tubes are connected properly and are | ||||
pushed down as far as possible. | of the connections. |
7