Manitowoc Ice S1000M Water Supply And Drain Line Sizing/Connections, Installation Instructions

Page 14
WATER SUPPLY AND DRAIN LINE SIZING/CONNECTIONS

Installation Instructions

Section 2

 

 

WATER SUPPLY AND DRAIN LINE SIZING/CONNECTIONS

!Caution

Plumbing must conform to state and local codes.

Location

Water Temperature

Water Pressure

Ice Machine Fitting

Tubing Size Up to Ice

Machine Fitting

 

 

 

 

Ice Making

35°F (1.6°C) Min.

20 psi (137.9 kPA) Min.

3/8" Female Pipe

3/8" (.95 cm) minimum

Water Inlet

90°F (32.2°C) Max.

80 psi (551.5 kPA) Max.

Thread

inside diameter

Ice Making

---

---

1/2" Female

1/2" (1.27 cm) minimum

Water Drain

Pipe Thread

inside diameter

 

 

Condenser

40°F (4.4°C) Min.

20 psi (137.9 kPA) Min.

3/8" Female Pipe Thread

Water Inlet

90°F (32.2°C) Max.

150 psi (1034.2 kPA) Max.

 

 

Condenser

---

---

1/2" Female

1/2" (1.27 cm) minimum

Water Drain

Pipe Thread

inside diameter

 

 

Bin Drain

---

---

3/4" Female

3/4" (1.91 cm) minimum

Pipe Thread

inside diameter

 

 

 

ELECTRICAL ENTRANCE

18” (46 CM) VENT TUBE

1/2” DRAIN CONNECTION

PLASTIC FITTING ON OPPOSITE

SIDE DO NOT APPLY HEAT

1/2” (1.3 CM) MIN

DRAIN ID

AIR GAP

OPEN, TRAPPED ANDPlumbing must conform to state and local codes.

VENTED DRAIN

3/8” FPT ICE MAKING WATER INLET FITTING, Typical Water Supply Drain Installation PLASTIC FITTING ON OPPOSITE SIDE DO NOT APPLY HEAT

3/8” FPT CONDENSER WATER INLET

(WATER COOLED UNITS ONLY

1/2” FPT CONDENSER WATER DRAIN

(WATER COOLED UNITS ONLY)

1/2” CPVC SOCKET AUXILLARY BASE

DRAIN

DO NOT TRAP DRAIN LINE,

 

LEAVE AIR GAP BETWEEN

SV3142

DRAIN TUBE AND DRAIN

Typical Water Supply Drain Installation

2-6

Part Number 80-1561-3

Image 14
Contents Installation Use and Care Manual S1000M Model Ice MachinesSafety Notices Read These Before ProceedingPERSONAL INJURY POTENTIAL Procedural NoticesManitowoc Cleaner and Sanitizer Table of Contents continued Section General InformationSection Installation Instructions AuCS Automatic Cleaning SystemSection Before Calling For Service Table of Contents continued Section Ice Machine OperationSection Maintenance Guardian Sachet Replacement FrequencySection How to Read a Model NumberSection General Information General InformationAUCS AUTOMATIC CLEANING SYSTEM AccessoriesMANITOWOC CLEANER AND SANITIZER BIN CASTERMODEL/SERIAL PLATE LOCATION Model/Serial Number LocationModel/Serial Number Location AUTHORIZED WARRANTY SERVICE Owner Warranty Registration CardWarranty Coverage Service CallsIce Machine Dimensions Section Installation InstructionsInstallation Instructions Width, Depth, and Height DimensionsThe location must be free of airborne and other contaminants Location of Ice MachineIce Machine Heat of Rejection FUSE/CIRCUIT BREAKER Electrical ServiceVOLTAGE MINIMUM CIRCUIT AMPACITYSELF CONTAINED ICE MACHINE 115/1/60 OR 208-230/1/60 Self-Contained Electrical Wiring ConnectionsFor United Kingdom Only SELF CONTAINED ICE MACHINE 208-230/3/60WATER SUPPLY Water Supply and Drain RequirementsCooling Tower Applications Water-Cooled Models AIR GAPPlumbing must conform to state and local codes Typical Water Supply Drain InstallationWATER SUPPLY AND DRAIN LINE SIZING/CONNECTIONS Installation Check List Is the Ice Machine level?Before Starting the Ice Machine Potential Personal Injury SituationComponent Identification Section Ice Machine OperationIce Machine Operation sv31492. Refrigeration System Start-Up Sequence Of OperationINITIAL START-UP OR START-UP AFTER AUTOMATIC SHUT-OFF 1. Water Purge FREEZE SEQUENCE 3. Prechill6. Harvest SAFETY TIMERSHARVEST SEQUENCE 5. Water Purge AUTOMATIC SHUT-OFF 7. Automatic Shut-OffICE THICKNESS CHECK Operational ChecksWATER LEVEL Ice Thickness Check45 second setting 0 second setting Water Purge AdjustmentHARVEST SEQUENCE WATER PURGE THIS PAGE INTENTIONALLY LEFT BLANK Exterior Cleaning Section MaintenanceMaintenance Ice Machine InspectionCLEAN UP PROCEDURE FOR DAMAGED SACHET PACKET SACHET INSTALLATION/REPLACEMENT PROCEDUREGuardian Location GUARDIAN SACHET REPLACEMENT FREQUENCY GuardianStep Interior Cleaning and SanitizingCLEANING PROCEDURE Remove all ice from the bin SANITIZING PROCEDURERefer to Removal of Parts For Cleaning 16 oz 500 ml cleaner REMOVAL OF PARTS FOR CLEANING/SANITIZINGCleaner 1 gal. 4 l2. Ice Thickness Probe 1. Water CurtainWater Curtain Removal Ice Thickness Probe RemovalWater Distribution Tube Removal 3. Water Distribution Tube4. Water Trough Water Pump Removal Water Level ProbeWater Pump PLUNGER SPRING STOP Dump Valve DisassemblyWater Dump Valve COIL SPRINGDrain Line Check Valve 4-10Evaporator Tray Removal Water Inlet Valve Removing the Front Panel4-11 Panel Removal4-12 Removal from Service/WinterizationPry Open the Water Regulating Valve AUCS→ Accessory SELF-CONTAINED WATER-COOLED ICE MACHINESChecklist Section Before Calling For ServiceBefore Calling For Service ProblemSafety Limit Feature Call for servicePage MANITOWOC ICE, INC 2004 Manitowoc Ice, Inc. Litho in U.S.A