Electrical System | Section 6 |
|
|
WATER FLOAT VALVE
Function
The float valve maintains correct water level during the Freeze cycle.
It allows the evaporator to drain completely during the Automatic
Check Procedure
1.Verify water is supplied to the float valve, the water inlet screen is clean, and the float and float arm are free moving.
2.Refer to the Energized Parts Chart and verify the following:
•The float valve coil should be energized.
•The red water valve LED on the control board is energized.
3.Check for line voltage at float valve coil. This test must be performed within 90 seconds of the water float valve energizing. If no water contacts the water level probes within 90 seconds, the valve will de- energize.
Step 3 Check for Line Voltage
Voltage Reading | Result |
|
|
| Replace Solenoid Coil |
Line Voltage | or |
| Replace Valve |
|
|
| See |
No Voltage | “Control Board Relays” |
| for further diagnostics. |
|
|
WATER LEVEL CHECK
The float valve maintains the correct water level. The water level must allow the water level probes to maintain water contact throughout the Freeze cycle. The water level is factory set and normally will not require adjustment. Check the water level during the Freeze cycle. The water level is correct if the Water Level indicator light is energized and no water is entering the overflow tube. (Check for overflow water exiting the ice machine drain line at the floor drain.)
If adjustments are necessary:
A.Rotate float clockwise to increase water level.
B.Rotate float counterclockwise to decrease water level.
Verify the outlet for the water float valve is at a 20° to 30° angle to prevent contact with the float.
| WATER FLOAT |
| VALVE SOLENOID |
| COIL |
VERIFY WATER |
|
OUTLET DOES | WATER FLOAT |
NOT POINT | VALVE |
STRAIGHT DOWN; |
|
IT MAY |
|
INTERFERE WITH |
|
FLOAT. |
|
WATER LEVEL
PROBE
WATER FLOAT
ROTATE TO
ADJUST WATER
LEVEL.
| Revised 8/2003 | Part No. |
|
|