Section 3 | Ice Machine Operation |
|
|
Water Reservoir Cover Removal
QF2300
1.Place the toggle switch in the OFF position, turn off the water supply and disconnect electrical power to the ice machine.
2.Remove water level probes.
3.Remove water float valve coil.
4.Depress coil and rotate 1/4 turn counterclockwise.
5.With coil wires attached, lift coil off enclosure tube.
6.Remove top cover from float reservoir.
3, 4, 5
2
6
SV1791
QF2300 Shown
Float Valve Removal
1.Place the toggle switch in the OFF position, turn off the water supply and disconnect electrical power to the ice machine.
2.Disconnect water supply line at float valve quick disconnect by depressing stainless steel lever.
3.Remove water float valve coil.
4.Depress coil and rotate 1/4 turn counterclockwise.
5.With coil wires attached, lift coil off enclosure tube.
6.QF0800/QC0700/QF2300 ONLY Rotate quarter turn fasteners counterclockwise.
7.QF0800/QC0700 ONLY Remove cotter key and pin from ice chute.
8.Remove top cover from float reservoir.
9.Lift float valve out of float reservoir.
FLOAT VALVE
SV2015
QC700/QF800 Shown
Part Number |
|