Ice Machine Operation | Section 3 |
|
|
Water Level Probe Removal
QF400/QC700/QF800/QF2300
Water Level Probe Removal
1.Place the toggle switch in the OFF position, turn off the water supply and disconnect electrical power to the ice machine.
2.Disconnect water supply line at float valve quick disconnect by depressing stainless steel lever.
3.Pull up on water level probes to remove.
4.Disconnect wires from water level probes or control board.
WATER LEVEL
PROBES
SV2043
QF400
WATER LEVEL
PROBES
SV2028
QC700/QF800
WATER LEVEL
PROBES
SV1791
QF2300
Water Reservoir Cover Removal
1.Place the toggle switch in the OFF position, turn off the water supply and disconnect electrical power to the ice machine.
2.Remove water level probes.
3.Remove water float valve coil.
4.Depress coil and rotate 1/4 turn counterclockwise.
5.With coil wires attached, lift coil off enclosure tube.
6.QF0800/QC0700 ONLY Rotate quarter turn fasteners counterclockwise.
7.QF0800/QC0700 ONLY Remove cotter key and pin from ice chute.
8.Remove top cover from float reservoir.
4
5 | 3 |
6
SV2030
QC700/QF800 Shown