Priming and Calibration
12.Press to arm the machine to take a long CAL shots. The icon will be highlighted (“”). Press to
13.Place a container on a scale and tare (zero) it.
14.Place the tared container below the static mixer, and press (green) or the footswitch.
15.Press to erase existing average weight data.
16.Place the container with the dispensed material on the tared scale.
17.Enter the mass in grams into the HMI, by pressing or accordingly.
18.Press to accept the number. The number entered will be transferred to the right of the average icon (“”).
19.Repeat steps 13 through 18, skipping step 15, several times. Each additional shot weight will be averaged in the row with the previous shots.
20.Press to
21.Press twice to return to the Run screen.
Shot Size Definition (M2)
To dispense in Shot Mode, one or more, up to 5, shot sizes need to be entered. This step is not required for Operator mode.
IScreen Number (M2).
J & keys will navigate to adjacent screens.
1. Press . The following screen will be displayed:
Figure 16: M2 Shot Definition Screen
2.Press or to select a shot number to define.
3.Press or to enter the shot size.
The shot size (in grams) must be greater than the Short CAL Shot size from the previous C4 calibration screen.
4.Press to accept the value or to retain the previous value.
5.Repeat the previous 2 steps for other shot sizes as required.
6.Press to exit the Shot Definition screen.
7.Press twice to return to the Run screen.
Ratio Checks
From the Run screen, press , then press , and then press once. The following screen will be displayed.
Figure 15: Shot Size and Purge Timer Screen (M2)
Key:
AShot Number
BShot Size (in grams).
CPurge Timer Setting (Turned OFF in Figure 15).
DPurge Timer Alarm Setting.
EDefine Shot ICON
FSet Purge Timer ICON
GPurge Timer Warning ICON.
Read all manufacturer’s warning and material MSDS to know the specific hazards of the material used.
This is a procedure to verify the weight ratio between the 2 materials. This is easiest to do with two scales.
1.From the Run screen, put the machine in Shot
mode (“”). See page 13.
2.Verify that the machine is properly calibrated and phased as outlined in the calibration section.
3.Remove any static mixer attached to the dispense valve and replace it with a ratio check nozzle. Place a waste container under the valve to capture any dispensed material.
4.Select a shot size between the Short and Long CAL shot sizes previously done, by pressing or and to accept.
5.Place the empty container below the Ratio Check Nozzle and the footswitch. Discard this shot.