Error Code Table
Error Code Table
Title | # | Cause, Details | ICON |
Stuck Key Error | E11 | A key on membrane has been active (pressed) for > 30 seconds continuously. |
|
|
| Replace the HMI. This error code does not require user acknowledgment and |
|
|
| will clear itself automatically if the condition is removed. |
|
|
|
|
|
Communication | E12 | The Display module has lost communication with the Fluid Control Module. |
|
Error |
| Material dispensing will be disabled if this condition exists. Check |
|
|
| communication cables between the 2 electronic components, or check the |
|
|
| HMI and/or the Fluid Control Module. |
|
|
| This error will be regenerated continuously while the condition exists. |
|
|
|
|
|
No or Invalid Run | E13 | The Run Token in the FCM is missing (not installed), or does not have the |
|
Token Error |
| correct data. |
|
|
|
|
|
Piston Stroke | E21 | A piston stroke action has taken > 55 seconds. Typically caused by no/too |
|
| little air pressure to the machine or a mechanical interference with the piston |
| |
|
| has occurred. Check machine input line pressure. |
|
|
|
|
|
Less than | E23 | User has requested a shot < the minimum allowable size entered during |
|
Minimum Shot |
| calibration. (< 15% of stoke, N/A in Operator Mode). |
|
Requested Error |
|
|
|
Improper | E24 | The calibration done on the machine is invalid, so the requested shot cannot |
|
Calibration Error |
| be executed. For instance, a Large Stroke Calibration Shot mass which is |
|
|
| less than the Short Stroke Calibration Shot mass (C4 screen) will create this |
|
|
| error code. If the wiring to the linear position transducer is reversed this error |
|
|
| will appear. If invalid piston positions are calibrated into the machine (C1 |
|
|
| screen) this error will appear. |
|
|
|
|
|
Delta Velocity | E25 | The piston velocity is slower than the calibration velocity measured, by the |
|
(“V”) Minus Error |
| percentage amount selected by the user (20%, 40% or 60%). If the user |
|
|
| selects 0%, this monitoring or alarm feature is disabled. |
|
|
| If generated, shot size accuracy may be degraded. Typically the problem is |
|
|
| created when the machine pressure regulator is adjusted to different value |
|
|
| from when the machine was calibrated. Another less likely cause could be a |
|
|
| mechanical failure with dispensing (worn piston, etc.). This error will not be |
|
|
| generated for a purge shot or when the machine is in Operator mode. |
|
|
|
|
|
Delta Velocity | E26 | The piston velocity is faster than the calibration velocity measured, by the |
|
(“V”) Plus Error |
| percentage amount selected by the user (20%, 40% or 60%). If the user |
|
|
| selects 0%, this monitoring or alarm feature is disabled. |
|
|
| If generated, shot size accuracy may be degraded. Typically the problem is |
|
|
| created when the machine pressure regulator is adjusted to different value |
|
|
| from when the machine was calibrated. Another less likely cause could be a |
|
|
| mechanical failure with dispensing (worn piston, etc.). This error will not be |
|
|
| generated for a purge shot, or when the machine is in Operator mode. |
|
|
|
|
|
Low Material | E27 | Tank A is low (only generated if tank sensing is enabled). Fill tank A with |
|
Level, Tank A |
| material. |
|
Alarm or Error |
| Tank level errors will be generated after every shot if the condition still exists. |
|
|
|
| |
|
|
|
|
Low Material | E28 | Tank B is low (only generated if tank sensing is enabled). Fill tank B with |
|
Level, Tank B |
| material. |
|
Alarm or Error |
| Tank level errors will be generated after every shot if the condition still exists. |
|
|
|
| |
|
|
|
|