Graco PR70 important safety instructions Electric Shock Hazard

Page 5

Warnings

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.

WARNING

ELECTRIC SHOCK HAZARD

Improper grounding, setup, or usage of the system can cause electric shock.

Turn off and disconnect power cord before servicing equipment.

Use only grounded electrical outlets.

Use only 3-wire extension cords.

Ensure ground prongs are intact on sprayer and extension cords.

Do not expose to rain. Store indoors.

SKIN INJECTION HAZARD

High-pressure fluid from dispense valve, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical

treatment.

Do not point dispense valve at anyone or at any part of the body.

Do not put your hand over the end of the dispense nozzle.

Do not stop or deflect leaks with your hand, body, glove, or rag.

Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment.

TOXIC FLUID OR FUMES HAZARD

Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed.

Read MSDS’s to know the specific hazards of the fluids you are using.

Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.

Always wear impervious gloves when spraying or cleaning equipment.

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:

Use and clean equipment only in well ventilated area.

Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc).

Keep work area free of debris, including solvent, rags and gasoline.

Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.

Ground equipment, personnel, object being sprayed, and conductive objects in work area. See Grounding instructions.

Use only Graco grounded hoses.

Check gun resistance daily.

If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem.

Do not flush with gun electrostatics on. Do not turn on electrostatics until all solvent is removed from system.

Keep a working fire extinguisher in the work area.

312393G

5 of 50

Image 5
Contents PR70 Contents Mixer and Shroud Options PR70 AccessoriesRelated Manuals Supplied ManualsPR70 Feed System DescriptionElectric Shock Hazard Equipment Misuse Hazard Locate and Install the PR70 InstallationMachine Setup General InformationKey Component IdentificationPR70 Top View with Shield, Tanks, DV and HMI Removed HMI Control and IndicatorsRun Screen Operation Setup Screens Machine Disable Mode redEntering the Setup Screens Setup Screens with Passwords EnabledPR70 Screen Navigation Diagram Piston Position Calibration C1 Machine PrimingMachine Calibration Phasing C2 Open Dispense Valve ODV Setting C3Open Dispense Valve ODV Screen C3 Key Machine Calibration Shots C4Ratio Checks Shot Size Definition M2Purge Timer / Alarm Settings M2 Miscellaneous Machine SetupsManual Control Options M1 Manual DV ControlM2 after Purge Shot Size Prompt Cycle Counter and Silent Mode Control M3Tank Level Sensing and Velocity Change Options C6 Date and Time Settings M4Setting/Clearing an Administrative Password Password Setup / Clearing C5To clear the password, enter Setting/Clearing a Maintenance only PasswordResetting Passwords HMI Hibernate Mode Miscellaneous Machine FeaturesHMI Demo Mode Operation Limitations of Demo Mode SimulationError Codes Pressure Relief ProcedureStandby/Shutdown Procedure Error Code Table E50 Error Code TableE29 Tables 3 PR70 Screen Icon Tables Key Key Description ScreenPR70 HMI Icon Table Tables 4 PR70 Screen Icon Tables Run Token MaintenanceSoftware Upgrades, Run Token Problem Cause Solution TroubleshootingMajor Mechanical Assemblies, and Attachments RepairPR70 Base Frame Assembly LC0109 Key Base Frame AssemblyAir Cylinder Assemblies, and Rebuild Kits PR70 Air Cylinder System and SchematicAir Cylinder Assemblies Pump Assembly Pump Assemblies and Rebuild Kits Drive Block AssemblyPR70 Check Valve Rebuild Kit LC0093 Key To install a new Check Valve Rebuild KitPR70 Rear Pump Rebuild Kit LC0094 Key To install a new Rear Pump Rebuild KitPiston Cylinders or Metering Tubes PR70 Nylon and Uhmwpe Piston Replacement Kits KeyNylon Pistons see Figure To install a new Piston or Piston/Cylinder Replacement KitAvailable PR70 Piston and Cylinder Metering Tubes Kits Key Hose Assemblies To install a new Piston Plug AssemblyHeated Piston to DV Hose Assemblies To Replace the Fuses Miscellaneous Mechanical AssembliesPR70 Control Bracket Assembly LC0108 Key PR70 Hydracheck Components PR70 Wiring Interconnect Illustration Wiring DiagramsWiring Diagram, PR70 Category Data Technical DataPR70 Dimensions ON-Board PE Tank version Illustrated DimensionsGraco Information Graco Ohio Standard Warranty