FIXING THE FRAME
•Lift the frame up, making sure that the index over the frame plate is turned forwards.
•Fit the frame slots onto the two screws inserted in the ceiling as above, and turn until reaching the centre of the adjustment slot.
•Tighten the two screws and fasten the other two screws pro- vided; before locking the screws completely, it is possible to adjust the frame by turning it, making sure that the screws do not come out of their housing in the adjustment slot.
•The Frame must be securely fastened so as to support both the weight of the Hood and the stress caused by occasional axial pressure against the fitted Appliance. After fixing, make sure that the base is stable even when the Frame is subjected to lat- eral stress.
•If the Ceiling is not strong enough in the area where the hood is to be fixed, the Installer must strengthen the area using suit- able plates and counter plates anchored to resistant structures.
1 | 1 | 2 |
2
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the chimney using a rigid 6” duct. (not supplied)
• | Install the damper 10a ø 6”. | 10a |
• | Fix the duct in position using sufficient pipe clamps. |
|
EN |
| 1 |
| 11 |