Franke Consumer Products FTU 3807 I installation instructions Electrical connection

Page 12

Installing of the chimney and fixing of the hood

When the hood is installed in recycling version the chimney has to be positioned with the slots upwards. When the hood is in- stalled in ducting version it has to be positioned in the opposite way.

Place the chimney on the frame and fix it to the upper part of it with the earlier removed screws. When installing the hood in recycling version make sure that the slots correspond to the air outlet of the recycling air outlet piece 15.

Open the lighting unit by slightly pulling the notch. Remove the unit from the hood by sliding the fixing pivot.

Remove the filter pushing it towards the back side of the hood unit and simultaneously pulling downwards.

Remove possible charcoal filters.

In order to fix the hood body to the frame insert the 4 screws 12f in their seats. It is necessary to leave at least 3/16”gap be- tween the screw heads and the frame plate.

Hook the hood canopy to the frame and turn it to the left until it reaches the stop, then lock the screws immediately to prevent the hood canopy from falling out accidentally.

Electrical connection

Remove the cover from the Field Wiring Compartment with a phillips screwdriver.

Feed the Power Supply Cable through the electrical knockout. Connect the Power Supply Cable to the range- hood cable. At- tach the Power Supply Cable grounding lead to the green screw provided. Attach the White lead of the power supply to the White lead of the rangehood with a twist-on type wire connec- tor. Attach the Black lead of the power supply to the Black lead of the rangehood with a twist-on type wire connector.

Replace the cover.

 

1

 

2

Green

Ground wire

Ground

 

screw

 

Power supply cable

• Connect the Cmd-connectors of the controls.

Lux

• Connect the Lux-connectors of the lighting system.

Cmd

EN

 

1

 

12

Image 12
Contents Tube Island Index Read and Save These Instructions R N I N G R N I N G Installation Recommendations and SuggestionsUSE CareDimensions and Main Parts Components Installation Drilling the Ceiling/shelf and fixing the frameDrilling the CEILING/SHELF Preparation of the Frame for the Hood in RE Cycling Version Connections Fixing the FrameDucted Version AIR Exhaust System Installing of the chimney and fixing of the hood Electrical connectionUSE Control boardCleaning the Comfort Panels Remote Control OptionalCare Alarm reset Metal grease filtersLight Replacement Charcoal filter ductless versionLighting Replacing the Charcoal FilterTable DES Matières 114115 116 117 Conseils ET Suggestions UtilisationEntretien Protecteur ThermiqueDimensions et Principales Pièces Composantes Réf. Qté Pièces du produitPerçage DU Plafond / DE L’ÉTAGÈRE Préparation DU Cadre Pour LA Hotte EN Version Recyclage Branchements Sortie D’AIR Version AspiranteInstallation de la cheminée et fixation de la hotte Branchement ÉlectriqueTableaux des commandes UtilisationTélécommande EN Option Soin ET EntretienNettoyage des panneaux Comfort Rétablissement du signal d’alarme Filtres à graisse métalliquesRemplacement DU Filtre ANTI-ODEUR AU Charbon Actif RemplacementFiltre anti-odeur au charbon actif version filtrante Éclairage43600392001