Franke Consumer Products FTU 3807 I installation instructions Use, Control board

Page 13

USE

A

D

B

C

E

F

G

H

Control board

Key

Function

Display

 

 

 

A

Switches the blower motor on and off at the

Indicates the selected speed.

 

latest selected speed

 

B

Decreases the vent speed.

 

 

 

 

C

Increases the vent speed.

 

 

 

 

D

By pressing this key it is possible to activate

HI appears. The spot down on the right side

 

the intensive speed from any previously se-

flashes once a second.

 

lected speed. The intensive speed can be acti-

 

 

vated even when the motor is OFF. This speed

 

 

has been timed at 10 minutes. After that time

 

 

the system activates automatically the latest

 

 

selected speed. This function is recommended

 

 

for cooking condition where vapors and odors

 

 

need to be eliminated immediately and quickly.

 

E

By pressing this key it is possible to set up the

Indicates the 24-function.The spot down on

 

motor to a suction speed at 60 CFM lasting 10

the right side flashes and the motor is on.

 

minutes every hour. After this the motor

Once the process is finished the previous indi-

 

switches off automatically.

 

cation disappears:

 

When the filter saturation is going on it is pos-

 

FF Indicates that the metal grease filters

 

sible to reset the alarm by pressing this key for

saturation alarm has been triggered, and

 

about 3 seconds. The indication is visible only

 

the filters need to be washed. The alarm

 

when the motor is off.

is triggered after 100 working hours.

 

 

EF Indicates that the charcoal filter satura-

 

 

tion alarm has been triggered, and the fil-

 

 

ter has to be replaced; the metal grease

 

 

filters must also be washed. The charcoal

 

 

filter is triggered after 200 working hours.

F

By pressing this key it is possible to set the

Indicates both the selected speed of the hood

 

delayed shutdown of the appliance to 30 min-

and the time left before the hood shutdown.

 

utes. This function is suitable for a complete

The spot down on the right side flashes alter-

 

elimination of the residual odors. It can be ac-

nately displaying the speed and shutdown time.

 

tivated at any position, and it is deactivated by

 

 

pressing the key again or by switching off the

 

 

motor.

 

G

Turns light on and off .

 

 

 

 

H

Turns light on and off at reduced intensity.

 

EN

 

1

 

13

Image 13
Contents Tube Island Index Read and Save These Instructions R N I N G R N I N G Recommendations and Suggestions InstallationUSE CareDimensions and Main Parts Components Drilling the Ceiling/shelf and fixing the frame InstallationDrilling the CEILING/SHELF Preparation of the Frame for the Hood in RE Cycling Version Fixing the Frame ConnectionsDucted Version AIR Exhaust System Electrical connection Installing of the chimney and fixing of the hoodControl board USERemote Control Optional Cleaning the Comfort PanelsCare Metal grease filters Alarm resetCharcoal filter ductless version Light ReplacementLighting Replacing the Charcoal Filter114 Table DES Matières115 116 117 Utilisation Conseils ET SuggestionsEntretien Protecteur ThermiqueDimensions et Principales Pièces Réf. Qté Pièces du produit ComposantesPerçage DU Plafond / DE L’ÉTAGÈRE Préparation DU Cadre Pour LA Hotte EN Version Recyclage Sortie D’AIR Version Aspirante BranchementsBranchement Électrique Installation de la cheminée et fixation de la hotteUtilisation Tableaux des commandesSoin ET Entretien Télécommande EN OptionNettoyage des panneaux Comfort Filtres à graisse métalliques Rétablissement du signal d’alarmeRemplacement Remplacement DU Filtre ANTI-ODEUR AU Charbon ActifFiltre anti-odeur au charbon actif version filtrante Éclairage43600392001