SCN60
Service
Performance and Technical Specs
Overall: | Light Blink Information |
•Refrigerant: 4.5 oz
•Compressor: Hermetic, 700 BTUH
•Condenser: Forced draft
•Fan blade: 3 blade, 6 inch
•Evaporator: Stainless steel tube, copper coil jacketed
•Metering device: Cap tube
•Auger drive: output speed 11 RPM
•Water valve: Float in reservoir
•Drain pump: Magnetic drive, controlled by pressure switch
•Bin control: Ultrasonic
Electrical Components:
•Compressor - 2.9 to 3.1 amps
•Fan motor
•Auger motor, amp draw .4 to .5amp
•Drain pump motor
•Drain pump switch
•Controller
•Transformer
•Water sensor
•Ice level sensor
•Membrane switch assembly
Control Timers
•Power interruption, time to restart after power restored: 2 minutes
•Auger motor overload, time to restart: 4 minutes
•Auger motor overload, restart window: 60 seconds
•Auger motor low current, time to restart: 20 minutes
•Auger motor low current, restart window: 60 seconds
•Clean cycle time: 40 minutes total.
Note: During the auger motor restart window times, there is no visible indication that the unit is in a restart mode.
•All blink once and repeat every 2 seconds: Auger motor overload
•All blink twice and repeat every 2 seconds: Auger motor low current
•All blink once and repeat every 10 seconds, controller failure.
•Water light blinks red: water supply failure
Controller Reset:
•Cycle power off and on
Diagnostic Codes: No diagnostic codes are kept
Time to Clean indicator light standard interval to switch light on is 6 months, it can be changed to once per year or disabled.
To Adjust:
1.From Off, press and hold the On/Off and Clean Reset Buttons for 5 seconds.
2.Press and Hold the Clean Reset Button for 5 seconds, then press On/Off. Then press On/off again to cycle thru the settings:
| Ice Making | Water | Time to |
| Clean | ||
|
|
| |
|
|
|
|
6 months | On | Off | Off |
1 year | Off | On | Off |
|
|
|
|
Disabled | Off | Off | On |
|
|
|
|
Light will automatically go out after a few seconds of inactivity. Press Time To Clean to lock in the new setting.
Quick reset of time to clean light: Press and hold the Clean Reset button for 3 seconds.
May 2011
Page 7