Plumbing - Pump Model
Drains | Water Supply |
There are two types of ice machine models, one that drains by gravity and one that has an internal drain pump.
Drain Pump Model drain installation
1.Locate the coil of 3/8” ID plastic drain tubing secured to the back of the unit.
2.Route the plastic drain tube from the back of the unit to the drain connection point.
The recommended water supply tubing is ¼ inch OD copper. Stainless steel flex or reinforced PCV tube may also be used. Install an easily accessible
The water connection is at the back of the cabinet. Connect using a compression fitting, one is supplied tied to the water inlet tube. When built in: Coil enough tubing behind the machine so it can be pushed into the cavity without kinking the tubing.
The drain connection point can be as high as 10 feet above the ice machine. The drain pump includes a check valve to prevent
IMPORTANT NOTE: Often an air gap is required by local codes between the ice maker drain tube and the drain receptacle.